<?xml version="1.0" encoding="utf-16"?><rss xmlns:a10="http://www.w3.org/2005/Atom" version="2.0"><channel><title>RA</title><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/RSS.ashx</link><description>RA Pages</description><lastBuildDate>Fri, 09 May 2008 08:01:43 +0200</lastBuildDate><a10:id>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/</a10:id><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=1</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=1</link><title>RA Page 1</title><description>MAKING MODERN LIVING POSSIBLE Components for CO2 applications in Industrial Refrigeration REFRIGERATION &amp;amp; AIR CONDITIONING DIVISION Application guide</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=2</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=2</link><title>RA Page 2</title><description /><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=3</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=3</link><title>RA Page 3</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Contents Page Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 General information about CO2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Design pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Material compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Water in CO2 systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Safety valves in CO2 systems' . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Danfoss sub-critical CO2 components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Coils for solenoid valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Pilot valve type CVP (XP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Hot-gas capacity for ICS with CVP (XP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Pressure transmitters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Liquid line filter driers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  Danfoss A/S (RA Marketing/MWA), 08 - 2007 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243 3</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=4</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=4</link><title>RA Page 4</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications 4 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243  Danfoss A/S (RA Marketing/MWA), 08 - 2007</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=5</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=5</link><title>RA Page 5</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Introduction The objective of this application guide is to provide an overview of which Danfoss Industrial Refrigeration products are suitable for use in CO2 applications. Today, Danfoss is offering a broad programme of industrial products applicable for CO2, however this is dependent on demands regarding the design pressure. The table on page 8 lists the components which are suitable for CO2 applications together with the maximum working pressure limits. For further background information about CO2 as a refrigerant, please refer to the Danfoss article &amp;quot;CO2 Refrigerant for Industrial Refrigeration&amp;quot;. General information about CO2 Design pressure There are a number of important factors to be taken into consideration when determining the design pressure. 1. Pressure during operation: The pressure during operation is dependent on actual system design (single stage, cascade system or CO2”brine” system) and the load variation. 2. Pressure during “stand still”: The pressure during stand still can be very high and this has to be taken into consideration: • Asmallseparaterefrigerationsystem can be used to keep the liquid temperature at a level, where the saturated pressure is lower than the design pressure • Designingthesystemwithanexpansion vessel of a size that prevents the pressure from exceeding the design pressure. • Designingtheplantsothatitcan withstand the saturated pressure at the design temperature (approx. 80 bar) Note: In the “IoR - Code of Practice” issued by the Institute of Refrigeration in London, the above mentioned tolerance is stated to be 20% 4. Temperature / pressure requrements for defrosting Depending on the actual design, different ways of defrosting can be applied (natural, water, electrical or CO2 hot gas defrosting). The CO2 hot gas defrosting is the most efficient, especially at low temperatures, but it also has the highest pressure demand. With a design pressure of PS=50-52 bar, it is possible to reach a defrosting temperature of approx. 9-10&amp;#176;C. The saturated pressure at 9&amp;#176;C is 43.9 bar g. By adding 10% for the safety valves and approx. 5% for pressure peaks, the requirement is for pressure PS ~ 50-52 bar g. There is not one common method to perform defrosting. All methods, as described above, are used, depending on the system, but also on the availability of suitable compressors and other components. From Danfoss’ experience, it would appear that the most common solution for industrial refrigeration applications is to use a small separate refrigeration system to limit the temperature of the liquid CO2. 3. Pressure tolerances for safety valves (10 – 15 %) Safety valves require a certain pressure difference (difference between set pressure and reseating pressure) to ensure that the valve is closed properly. Normally the closing tolerance is 10% of the set pressure. Additionally, it is good practice to add 3-5% to the closing tolerance, to take care of any pressure variations / peaks.  Danfoss A/S (RA Marketing/MWA), 08 - 2007 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243 5</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=6</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=6</link><title>RA Page 6</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Material compatibility CO2 is compatible with almost all common metallic materials, unlike NH3. There are no restrictions from a compatibility point of view, when using copper or brass. The compatibility of CO2 and polymers is much more complex. As CO2 is a very inert and stable substance, the chemical reaction with polymers is not critical. The main concern with CO2 is the physiochemical effects, such as permeation, swelling and the generation of cavities and internal fractures. These effects are connected with the solubility and diffusivity of CO2 in the actual material. Danfoss has carried out a number of tests to ensure that components released for use with CO2 can withstand the impact of CO2 in all aspects. The tests have shown that CO2 is different, and modifications have to be made on some products. The large amount of CO2, which can dissolve in polymers, has to be taken into consideration. Some commonly used polymers are not compatable with CO2, and others require different fixing methods e.g. sealing materials. When the pressure is close to the critical pressure and the temperature is high, the impact on polymers is much more extreme. However, those conditions are not important for industrial refrigeration as pressure and temperatures are lower for these systems. 6 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243  Danfoss A/S (RA Marketing/MWA), 08 - 2007</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=7</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=7</link><title>RA Page 7</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Water in CO2 systems In NH3 systems it is well known that there are problems as a result of reaction with oil, oxygen, water and solid contaminations, but these are all handled today by frequent oil changes and use of air purgers. Compared to NH3 CO2 is less sensitive, but if water is present, problems may occur. How can water penetrate into a CO2 system? • ThepressureofCO2 systems is always above the atmospheric pressure, therefore there are not the same risks as in e.g. NH3 systems, of air/water penetration into a leaking CO2 system. However, pemeation of water into the system is still possible. • WhenchargingCO2, there are different grades of CO2, some of which allow relatively high amounts of water. • CO2 is a safe refrigerant, and therefore there is a risk, that it is handled without following the normal refrigeration safety requirements. If a system is opened up, air can penetrate into it, and the moisture can condense inside the tubes. If the system is not evacuated properly, some water may well be retained. • Bycharginglubricant(oil)tothecompressor. • Incompletewaterremovalduringinstallation/ commissioning From the reports, it seems that incomplete water removal, due to insufficient vacuum procedure, is one of the main reasons for water contamination in CO2 systems. Vacuum procedures sufficient for ammonia systems are not sufficient for CO2 systems. The acceptable amount of water in CO2 systems is much lower than in systems with other common refrigerants. If the water content exceeds the dew-point, and the temperature is below 0&amp;#176;C, the water will freeze, creating a risk of problems with equipment in the system e.g. blocking control valves. The water can very easily be removed by mounting a drier in the system. Driers in CO2 are very efficient, and are normally mounted in the liquid line to avoid any unnecessary pressure drops being created. Water solubility in liquid / vapour CO2 1200 Liquid CO2 Weight *10-6 of water / weight of refrigerant [ppm] 1000 800 600 400 200 Vapour CO2 0 -60 -76 -40 -40 -20 -4 0 32 Temperature 20 68 40 104 60 [ oC] 140 [ F] o Fig. 1: Water solubility Fig. 1 shows the maximum (water) moisture content that can be dissolved in the liquid and gas phases of CO2.  Danfoss A/S (RA Marketing/MWA), 08 - 2007 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243 7</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=8</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=8</link><title>RA Page 8</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Weight *10-6 of water / weight of refrigerant [ppm] Water in CO2 systems (cont.) Water solubility in vapour CO2 100 90 80 70 60 50 40 30 20 10 0 CO2 + ICE CO2 + Water CO2 + H2O vapour phase –40 –40 –20 –4 Temperature 0 32 20 &amp;#176;C 68 &amp;#186;F Water solubility in vapour phase 2000 Weight * 10-6 of water / weight of refrigerant [ppm] R717 1500 R134a 1000 500 CO2 0 -60 -76 -40 -40 -20 -4 0 32 Temperature 20 68 40 104 60 [&amp;#176;C] 140 [&amp;#176;F] Fig. 2: Water solubility In fig. 2, the maximum water content, which can be dissolved in the CO2 gas phase, is compared with other commonly used refrigerants. The maximum water content for CO2 is much lower than for the other refrigerants. If the maximum concentration is exceeded, this will appear as free water or as ice in the refrigeration system. Fig. 3: SGN moisture indication for CO2 An indication of water content can be obtained by using a Danfoss SGN sight glass. - A “dry” system is shown with a green indicator - A “wet” system is shown with a yellow indicator Water/moisture content values for these conditions are shown in fig. 3 8 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243  Danfoss A/S (RA Marketing/MWA), 08 - 2007</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=9</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=9</link><title>RA Page 9</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Water in CO2 systems (cont.) Principle diagram: CO2-NH3 cascade system Dry suction CO2 Compressor Filter drier CO2 reciever CO2 Evaporator Moisture indicator Filter drier Liquid CO 2 - NH 3 heat exchanger Filter driers installed in: • bypass lines or • main liquid line Liquid Moisture indicator Fig. 4: CO2 systems with DCR filter drier and SGN indicator Safety valves in CO2 systems Due to the thermodynamic properties of CO2, in particular the triple point, which is located at much higher pressure than for all other common refrigerants, the formation of solid CO2 can occur. If a safety valve is mounted in a CO2 system at e.g. 52 bar, the pressure in the downstream (outlet) line from the safety valve will pass the triple point at 5.2 bar. Below the triple point, CO2 will change from a mixture of liquid and vapour into a mixture of solid and vapour. The formation of solid CO2 in the downstream line can, in the worst case, block this line. Pressure psi 1450 bar 100 The most effective solution to this problem is to mount the safety valve without an outlet line, thus blowing directly into the atmosphere. The phase change of the CO2 does not take place directly in the valve, but just after the valve, and in this case in the atmosphere. If safety valves or any other safety devices, have to be mounted in liquid lines, they must never blow to the atmosphere or any other places where the backpressure is below 5.2 bar. If the back-pressure is below the triple point (5.2 bar) a very high fraction of the CO2 will be solid. +31&amp;#176;C [87.9&amp;#176;F] 50 bar [725 psi] Liquid 20 bar [290 psi] Vapour Vapour 35 bar [507 psi] 145 10 0% solid CO2 at 50% solid CO2 at the triple point the triple point –56.6&amp;#176;C [–69.9&amp;#176;F] –5.2 bar-a [75.1 psi-a] 3% solid CO2 at the triple point 14.5 1 –78.4&amp;#176;C [–109.1&amp;#176;F] Fig. 5: Flow in downstream lines from safety valves Enthalpy (J) Capacity CO2 capacity calculations for Danfoss Industrial Refrigeration components can be undertaken using the DIRcalc selection software.  Danfoss A/S (RA Marketing/MWA), 08 - 2007 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243 9</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=10</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=10</link><title>RA Page 10</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Danfoss sub-critical CO2 components Today, Danfoss is offering a broad programme of industrial components applicable for CO2. The majority of components listed below have been evaluated and upgraded, and are therefore applicable for CO2 within the pressure and temperature range stated in the technical documentation. In particular the pressure is the limiting factor for this group of components. Special components for “high” pressure CO2 applications have been developed. The most common types of valves are listed on the following pages. Please note the high pressure specials are generally available to order only and extended delivery times should be considered. Pressure Equipment Directive (PED) The Industrial Refrigeration valves are approved in accordance with the European standards specified in the Pressure Equipment Directive and are CE marked. Design pressure / temperature for CO2 bar psi 60 870 Design pressure ”p” + 15% (barg / psig) ”p” + 10% (barg / psig) Design pressure 50 725 52 bar 754 psi 40 580 40 bar 580 psi ”Saturated” pressure”p” (bara / psia) 30 435 25 bar 363 psi 20 290 –30 –22 –20 –4 –10 0 14 32 Design temperature 10 50 20 68 &amp;#176;C &amp;#176;F Industrial Refrigeration products Danfoss Sub Critical CO2 - components Industrial Refrigeration products Main Valves, Solenoid Valves Motor Valves Multifunction valve Pilots for ICS Valves Stop Valves - SVA ST,HS Regulating Valves - REG Stop Check Valves SCA Filters FIA Check Valves Solenoid Valves Electrically operated expansion valve Safety Valves and Change Over Valves SFV - DSV ICS 1 ICS 3 ICM ICF CVP (XP) EVM SVA SVA REG SCA SCA FIA FIA CHV CHV EVRS EVRA AKVA SFA DSV POV DCRH AKS 41 GD all all all DN PS 40bar [580 psi] PS 52 bar [754 psi] 20-65 20-65 20-40 # # 50 bar # # 50 bar # 50 bar # 50 bar # Filter drier Liquid level transmitter Gas detectors all all all all all all all all all all all all 15 1, 2 40, 50, 80 High pressure version - 10-65 80-200 15 - 65 15-65 80-125 15-65 80-200 15- 40 80-125 10-25 10-40 10-40 20-32 40-80 - # # # # 46 bar # The product can be used in standard version. All products are CE approved # Code numbers for these products are available in this application guide. The product must be manufactured in a special version (higher test pressure, marking and documentation). All products are CE approved 10 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243  Danfoss A/S (RA Marketing/MWA), 08 - 2007</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=11</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=11</link><title>RA Page 11</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Danfoss sub-critical CO2 components (Continued) Commercial Refrigeration products Danfoss Sub Critical CO2 - components Commercial Refrigeration products Solenoid Valves Thermostatic expansion valves Shutoff Valves (Ball Valves) Check Valves Electrically operated expansion valve Filter drier EVR 2, EVR 3 EVRH 6 - EVRH 15 TU GBC NRV NRVH AKV 10 - AKV 15 (type A, B, C) DCRH DCR DML Moisture indicator Pressure controls Pressure transmitters Controllers for CO2-applications: Case controllers AKC 114A, AKC 115A, AKC 116A EKC 414A, EKC 414A1, AK-CC 550 AK-CC 750 Evaporator controllers Pack controllers EKC 315A, EKC 316, EKD 316, EKC 312 EKC 331T, AK-PC 530, AK-PC 420, AK-PC 730, AK-PC 840, AK-CH 650 SGN KP6 AKS 3000 34 bar 45 bar PS 35 bar [508 psi] PS 42bar [609 psi] PS 46 bar [667 psi] The product can be used in standard version. All products are CE approved  Danfoss A/S (RA Marketing/MWA), 08 - 2007 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243 11</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=12</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=12</link><title>RA Page 12</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Coils for solenoid valves Due to the high pressure difference between the condenser and evaporator, the Maximum Opening Pressure Differential (MOPD) demand for the solenoid valve in some applications may exceed the standard coil capabilities. Typical applications could be: Liquid injection for cooling the compressor Hot gas defrost Shut off valve before expansion valve Therefore Danfoss offers a 20 W coil, that covers a MOPD range up to 40 bar. The 20 W coil program includes 24, 110 and 230 V a.c. 50 Hz power supplies. Pilot valve type CVP (XP) Suction line Liquid line Hot gas line The figure shows the evaporator in a CO2 refrigeration plant with flooded evaporation and with pump circulation. In this application the Technical data Max working pressure: 52 bar g (754 psig) Kv /Cv value: 0.45 m3/h (0.52 USgal/min) Valve type Defrosting temperature Evaporating temperature CVP (XP) + CVH ICS 25-5 ICS 25-10 ICS 25-15 Defrosting capacity Defrosting mass flow Defrosting capacity Defrosting mass flow Defrosting capacity Defrosting mass flow Defrosting capacity Defrosting mass flow [&amp;#176;C] [bar] [&amp;#176;C] [bar] [kW] [kg/h] [kW] [kg/h] [kW] [kg/h] [kW] [kg/h] 0 34.9 1004 57 3792 217 6477 371 9647 552 -10 26.5 1353 79 5110 298 8728 509 13000 758 constant defrost pressure regulation is made by means of an ICS mounted with a high-pressure pilot valve type CVP(XP). Temperature range: –50 &amp;#221; 120&amp;#176;C (–58 &amp;#221; 248&amp;#176;F) Pressure range: 25 &amp;#221; 52 bar g (363 &amp;#221; 754 psig) +10 45.0 -20 19.7 1580 93 5969 351 10195 600 15185 893 -30 14.3 1687 102 6573 386 11227 659 16722 982 -40 10.1 1854 108 7004 408 11963 697 17818 1038 Hot-gas capacity for ICS with CVP (XP) 12 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243  Danfoss A/S (RA Marketing/MWA), 08 - 2007</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=13</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=13</link><title>RA Page 13</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Pressure transmitters AKS 3000 is a series of absolute transmitters with high-level signal conditioned current output, developed to meet demands in A/C and refrigeration. AKS 3000 utilises the proved piezoresistive measuring principle, which has been used for decades in Danfoss pressure transmitters. The pressure reference is a sealed gauge. This means that atmospheric pressure variations have no influence on regulating accuracy. A must in accurate low pressure regulation. All materials in contact with the refrigerant and materials for the housing are AISI 316L stainless steel. No soft gaskets, all environmental sealings are made through laser weldings only. AKS 3000 has a 4 to 20 mA output, and is available with DIN 43650-A plug RG9. Features Designed to meet A/C and refrigeration demands without compromising control accuracy concerning Tough environment • Vibration • Shock during operation and transport • Humidity and ice formation • Temperature variations • Corrosive media like ammonia gases and salt mist Convenient performance • 4 to 20 mA signal • 1% typical accuracy • 0.5% typical linearity • Prepared for high pressure refrigerants • Bar code for tracing of calibration data Perfect system integrity • Compact design • Max. working pressure ≤ 100 bar • Temperature compensation for suction line • 1/4 -18 NPT or G &amp;#189;” EN 387 pressure connection • All laser welded AISI 316L stainless steel enclosure • No soft seals • Enclosure: IP 65 with plug Application • High pressure control • Compressor capacity control • Evaporator pressure detection • Oil pressure control Approvals • UL • CE marked acc. to the EMC directive  Danfoss A/S (RA Marketing/MWA), 08 - 2007 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243 13</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=14</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=14</link><title>RA Page 14</title><description>Application guide Eliminator &amp;#174; liquid line filter driers Industrial Refrigeration Valves for CO2 Applications Eliminator &amp;#174; liquid line filter driers protect refrigeration and air-conditioning systems from moisture, acids, and solid particles. With these contaminants eliminated, systems are safer from harmful chemical reactions and from abrasive impurities. For further information regarding DCR filter driers please contact your local Danfoss sales company. Benefits, features and facts Excellent moisture and acid adsorption protects your refrigeration system Highly efficient dirt retaining capabilities on both the suction and the liquid line Corrosion-resistant powder-painted finish including zinc phosphate pre-treatment of the DCR shells DM solid core - 100% molecular sieve Max. working pressure High pressure version: 46 bar (667 psi) For industrial refrigeration available in connections: Butt weld DN20-50 (3/4 -2 in.) Capacity Please see the technical leaflet PD.EJ0.A 14 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243  Danfoss A/S (RA Marketing/MWA), 08 - 2007</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=15</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=15</link><title>RA Page 15</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Ordering The following list details the most commonly used Danfoss refrigeration components for CO2 applications. Components with alternative types of connections and dimensions can be supplied on request. The Code Numbers specified include a mix of special high pressure and standard products. In both cases the Maximum Working Pressures should be adhered to. Stop valve Size mm 10 10 10 15 15 15 20 20 20 25 25 25 32 32 32 40 40 40 50 50 50 65 65 65 80 80 100 100 125 125 150 150 200 200 in. 3 3 3 1 1 1 3 3 3 The list also includes components which are not suitable for use with NH3, but are suitable for use for CO2 systems (moisture indicators and filter driers). Type /8 /8 /8 /2 /2 /2 /4 /4 /4 SVA-ST 10 D ANG STOP VALVE CAP 52BAR SVA-ST 10 D ANG STOP VALVE H-WHEEL 52BAR SVA-ST 10 D STR STOP VALVE CAP 52BAR SVA-ST 15 D ANG STOP VALVE CAP 52BAR SVA-ST 15 D ANG STOP VALVE H-WHEEL 52BAR SVA-ST 15 D STR STOP VALVE CAP 52BAR SVA-ST 20 D ANG STOP VALVE CAP 52BAR SVA-ST 20 D ANG STOP VALVE H-WHEEL 52BAR SVA-ST 20 D STR STOP VALVE CAP 52BAR SVA-ST 25 D ANG STOP VALVE CAP 52BAR SVA-ST 25 D ANG STOP VALVE H-WHEEL 52BAR SVA-ST 25 D STR STOP VALVE CAP 52BAR SVA-ST 32 D ANG STOP VALVE CAP 52BAR SVA-ST 32 D ANG STOP VALVE H-WHEEL 52BAR SVA-ST 32 D STR STOP VALVE CAP 52BAR SVA-ST 40 D ANG STOP VALVE CAP 52BAR SVA-ST 40 D ANG STOP VALVE H-WHEEL 52BAR SVA-ST 40 D STR STOP VALVE CAP 52BAR SVA-ST 50 D ANG STOP VALVE CAP 52BAR SVA-ST 50 D ANG STOP VALVE H-WHEEL 52BAR SVA-ST 50 D STR STOP VALVE CAP 52BAR SVA-ST 65 D ANG STOP VALVE CAP 52BAR SVA-ST 65 D ANG STOP VALVE H-WHEEL 52BAR SVA-ST 65 D STR STOP VALVE CAP 52BAR SVA-ST 80 D ANG STOP VALVE CAP 50BAR SVA-ST 80 D STR STOP VALVE CAP 50BAR SVA-ST100 D ANG STOP VALVE CAP 50BAR SVA-ST100 D STR STOP VALVE CAP 50BAR SVA-ST125 D ANG STOP VALVE CAP 50BAR SVA-ST125 D STR STOP VALVE CAP 50BAR SVA-ST150 D ANG STOP VALVE CAP 50BAR SVA-ST150 D STR STOP VALVE CAP 50BAR SVA-ST200 D ANG STOP VALVE CAP 50BAR SVA-ST200 D STR STOP VALVE CAP 50BAR Max. WorkingPressure 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) Connection DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN Code Number 148B3829 148B3830 148B3859 148B3831 148B3832 148B3862 148B3815 148B3833 148B3897 148B3834 148B3835 148B3898 148B3836 148B3837 148B3899 148B3838 148B3839 148B3991 148B3840 148B3841 148B3992 148B3791 148B3842 148B3993 148B4293 148B4248 148B3779 148B3994 148B3995 148B3996 148B4294 148B3997 148B3998 148B4295 1 1 1 11/4 11/4 11/4 11/2 11/2 11/2 2 2 2 21/2 21/2 21/2 3 3 4 4 5 5 6 6 8 8 D = Butt weld DIN connection ANSI = Butt weld ANSI connection STR = Straightway ANG = Angleway CAP = Cap H-WHEEL = Hand wheel  Danfoss A/S (RA Marketing/MWA), 08 - 2007 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243 15</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=16</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=16</link><title>RA Page 16</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Ordering (cont.) Regulating valve Size mm 15 15 15 15 15 15 15 20 20 20 20 20 20 20 25 25 25 25 25 25 25 32 32 32 32 32 40 40 40 40 40 50 65 in. 1 1 1 1 1 1 1 3 3 3 3 3 3 3 Type /2 /2 /2 /2 /2 /2 /2 /4 /4 /4 /4 /4 /4 /4 REG 15 D ANG CONE#4 REG VALVE 52BAR REG 15 D ANG CONE#5 REG VALVE 52BAR REG 15 D ANG CONE#6 REG VALVE 52BAR REG 15 D ANG CONE#7 REG VALVE 52BAR REG 15 D STR CONE#4 REG VALVE 52BAR REG 15 D STR CONE#6 REG VALVE 52BAR REG 15 D STR CONE#7 REG VALVE 52BAR REG 20 D ANG CONE#4 REG VALVE 52BAR REG 20 D ANG CONE#5 REG VALVE 52BAR REG 20 D ANG CONE#6 REG VALVE 52BAR REG 20 D ANG CONE#7 REG VALVE 52BAR REG 20 D STR CONE#5 REG VALVE 52BAR REG 20 D STR CONE#6 REG VALVE 52BAR REG 20 D STR CONE#7 REG VALVE 52BAR REG 25 D ANG CONE#4 REG VALVE 52BAR REG 25 D ANG CONE#5 REG VALVE 52BAR REG 25 D ANG CONE#6 REG VALVE 52BAR REG 25 D ANG CONE#7 REG VALVE 52BAR REG 25 D STR CONE#5 REG VALVE 52BAR REG 25 D STR CONE#6 REG VALVE 52BAR REG 25 D STR CONE#7 REG VALVE 52BAR REG 32 D ANG CONE#10 REG VALVE 52BAR REG 32 D ANG CONE#8 REG VALVE 52BAR REG 32 D ANG CONE#9 REG VALVE 52BAR REG 32 D STR CONE#10 REG VALVE 52BAR REG 32 D STR CONE#8 REG VALVE 52BAR REG 40 D ANG CONE#10 REG VALVE 52BAR REG 40 D ANG CONE#8 REG VALVE 52BAR REG 40 D ANG CONE#9 REG VALVE 52BAR REG 40 D STR CONE#10 REG VALVE 52BAR REG 40 D STR CONE#8 REG VALVE 52BAR REG 50 D ANG CONE#11 REG VALVE 52BAR REG 65 D ANG CONE#12 REG VALVE 52BAR Max. Working Pressure 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) Connection DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN Code Number 148G3172 148G3173 148G3174 148G3175 148G3675 148G3691 148G3692 148G3176 148G3177 148G3178 148G3179 148G3676 148G3677 148G3693 148G3180 148G3181 148G3182 148G3183 148G3678 148G3694 148G3695 148G3184 148G3185 148G3186 148G3696 148G3679 148G3187 148G3188 148G3189 148G3680 148G3681 148G3190 148G3191 1 1 1 1 1 1 1 11/4 11/4 11/4 11/4 11/4 11/2 11/2 11/2 11/2 11/2 2 21/2 Stop check valve Size mm 15 25 32 40 50 50 65 80 100 125 in. 1 Type /2 SCA 15 D ANG STOP/CHECK VALVE 52BAR SCA 25 D ANG STOP/CHECK VALVE 52BAR SCA 32 D ANG STOP/CHECK VALVE 52BAR SCA 40 D ANG STOP/CHECK VALVE 52BAR SCA 50 D ANG STOP/CHECK VALVE 52BAR SCA 50 D ANG STOP/CHECK VALVE 52BAR SCA 65 D ANG STOP/CHECK VALVE 52BAR SCA 80 D ANG STOP/CHECK VALVE 50BAR SCA100 D ANG STOP/CHECK VALVE 50BAR SCA125 D ANG STOP/CHECK VALVE 50BAR Max. Working Pressure 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) Connection DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN Code Number 148G3522 148G3523 148G3524 148G3525 148G3672 148G3424 148G3425 148G3668 148G3697 148G3698 1 11/4 11/2 2 2 21/2 3 4 5 D = Butt weld DIN connection ANSI = Butt weld ANSI connection STR = Straightway ANG = Angleway 16 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243  Danfoss A/S (RA Marketing/MWA), 08 - 2007</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=17</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=17</link><title>RA Page 17</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Ordering (cont.) Check valve Size mm 15 20 25 32 40 40 50 65 80 100 125 in. 1 3 Type /2 /4 CHV 15 D ANG CHECK VALVE 52BAR CHV 20 D ANG CHECK VALVE 52BAR CHV 25 D ANG CHECK VALVE 52BAR CHV 32 D ANG CHECK VALVE 52BAR CHV 40 A ANG CHECK VALVE 52BAR CHV 40 D ANG CHECK VALVE 52BAR CHV 50 D ANG CHECK VALVE 52BAR CHV 65 D ANG CHECK VALVE 52BAR CHV 80 D ANG CHECK VALVE 50BAR CHV100 D ANG CHECK VALVE 50BAR CHV125 D ANG CHECK VALVE 50BAR Max. Working Pressure 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) Connection DIN DIN DIN DIN ANSI DIN DIN DIN DIN DIN DIN Code Number 148G3526 148G3527 148G3528 148G3529 148G3673 148G3530 148G3531 148G3426 148G3669 148G3699 148G3700 1 11/4 11/2 11/2 2 21/2 3 4 5 Filter Size mm 15 15 20 20 25 25 32 32 32 40 40 50 50 65 65 80 80 100 100 125 125 150 150 200 200 in. 1 1 3 3 Type /2 /2 /4 /4 FIA 15 D ANG FILTER HOUSING 52BAR FIA 15 D STR FILTER HOUSING 52BAR FIA 20 D ANG FILTER HOUSING 52BAR FIA 20 D STR FILTER HOUSING 52BAR FIA 25 D ANG FILTER HOUSING 52BAR FIA 25 D STR FILTER HOUSING 52BAR FIA 32 A STR FILTER HOUSING 52BAR FIA 32 D ANG FILTER HOUSING 52BAR FIA 32 D STR FILTER HOUSING 52BAR FIA 40 D ANG FILTER HOUSING 52BAR FIA 40 D STR FILTER HOUSING 52BAR FIA 50 D ANG FILTER HOUSING 52BAR FIA 50 D STR FILTER HOUSING 52BAR FIA 65 D ANG FILTER HOUSING 52BAR FIA 65 D STR FILTER HOUSING 52BAR FIA 80 D ANG FILTER HOUSING 50BAR FIA 80 D STR FILTER HOUSING 50BAR FIA100 D ANG FILTER HOUSING 50BAR FIA100 D STR FILTER HOUSING 50BAR FIA125 D ANG FILTER HOUSING 50BAR FIA 125 D STR FILTER HOUSING 50BAR FIA150 D ANG FILTER HOUSING 50BAR FIA150 D STR FILTER HOUSING 50BAR FIA200 D ANG FILTER HOUSING 50BAR FIA200 D STR FILTER HOUSING 50BAR Max. Working Pressure 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) 50 bar (725 psi) Connection DIN DIN DIN DIN DIN DIN ANSI DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN Code Number 148H3215 148H3313 148H3195 148H3314 148H3216 148H3315 148H3300 148H3217 148H3316 148H3218 148H3371 148H3219 148H3317 148H3220 148H3372 148H3373 148H3374 148H3375 148H3376 148H3377 148H3318 148H3378 148H3379 148H3380 148H3381 1 1 11/4 11/4 11/4 11/2 11/2 2 2 21/2 21/2 3 3 4 4 5 5 6 6 8 8 Code numbers include bodies only - filter inserts to be ordered separately Overflow valve Size mm 20 25 in. 3 Type /4 OFV D ANG OVERFLOW VALVE OFV D ANG OVERFLOW VALVE Max. Working Pressure 52 bar (754 psi) 52 bar (754 psi) Connection DIN DIN Code Number 148G3192 148G3193 1 The differential pressure can be adjusted 2-8 bar D = Butt weld DIN connection ANSI = Butt weld ANSI connection STR = Straightway ANG = Angleway  Danfoss A/S (RA Marketing/MWA), 08 - 2007 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243 17</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=18</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=18</link><title>RA Page 18</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Ordering (cont.) Stop valve (stainless steel) Size mm 15 15 65 65 20 20 20 20 25 25 25 25 32 32 32 32 40 40 40 40 50 50 50 50 65 65 65 65 in. 1 /2 1 /2 21/2 21/2 3/ 4 3/ 4 3/ 4 3/ 4 1 1 1 1 11/4 11/4 11/4 11/4 11/2 11/2 11/2 11/2 2 2 2 2 21/2 21/2 21/2 21/2 Type SVA-SS 15 D ANG STOP VALVE CAP 52BAR SVA-SS 15 D ANG STOP VALVE H-WHEEL 52BAR SVA-SS 15 D STR STOP VALVE CAP 52BAR SVA-SS 15 D STR STOP VALVE H-WHEEL 52BAR SVA-SS 20 D ANG STOP VALVE CAP 52BAR SVA-SS 20 D ANG STOP VALVE H-WHEEL 52BAR SVA-SS 20 D STR STOP VALVE CAP 52BAR SVA-SS 20 D STR STOP VALVE H-WHEEL 52BAR SVA-SS 25 D ANG STOP VALVE CAP 52BAR SVA-SS 25 D ANG STOP VALVE H-WHEEL 52BAR SVA-SS 25 D STR STOP VALVE CAP 52BAR SVA-SS 25 D STR STOP VALVE H-WHEEL 52BAR SVA-SS 32 D ANG STOP VALVE CAP 52BAR SVA-SS 32 D ANG STOP VALVE H-WHEEL 52BAR SVA-SS 32 D STR STOP VALVE CAP 52BAR SVA-SS 32 D STR STOP VALVE H-WHEEL 52BAR SVA-SS 40 D ANG STOP VALVE CAP 52BAR SVA-SS 40 D ANG STOP VALVE H-WHEEL 52BAR SVA-SS 40 D STR STOP VALVE CAP 52BAR SVA-SS 40 D STR STOP VALVE H-WHEEL 52BAR SVA-SS 50 D ANG STOP VALVE CAP 52BAR SVA-SS 50 D ANG STOP VALVE H-WHEEL 52BAR SVA-SS 50 D STR STOP VALVE CAP 52BAR SVA-SS 50 D STR STOP VALVE H-WHEEL 52BAR SVA-SS 65 D ANG STOP VALVE CAP 52BAR SVA-SS 65 D ANG STOP VALVE H-WHEEL 52BAR SVA-SS 65 D STR STOP VALVE CAP 52BAR SVA-SS 65 D STR STOP VALVE H-WHEEL 52BAR Max. Working Pressure 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) Connection DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN Code Number 148B3843 148B3844 148B4249 148B4250 148B3845 148B3846 148B4251 148B4252 148B3847 148B3848 148B3847 148B3848 148B3849 148B3850 148B4255 148B4256 148B3851 148B3852 148B4257 148B4258 148B3853 148B3854 148B4259 148B4260 148B3855 148B3856 148B4261 148B4262 Regulating valve (stainless steel) Size mm 15 15 15 15 15 15 15 15 20 20 20 20 20 20 20 20 25 25 25 25 25 25 25 25 32 32 32 32 32 32 40 40 40 40 40 40 in. 1/ 2 1/ 2 1/ 2 1/ 2 1/ 2 1/ 2 1/ 2 1 /2 3/ 4 3/ 4 3/ 4 3/ 4 3 /4 3 /4 3/ 4 3/ 4 1 1 1 1 1 1 1 1 11/4 11/4 11/4 11/4 11/4 11/4 11/2 11/2 11/2 11/2 11/2 11/2 Type REG-SS 15 D ANG CONG#4 REG VALVE 52BAR REG-SS 15 D ANG CONG#5 REG VALVE 52BAR REG-SS 15 D ANG CONG#6 REG VALVE 52BAR REG-SS 15 D ANG CONG#7 REG VALVE 52BAR REG-SS 15 D STR CONG#4 REG VALVE 52BAR REG-SS 15 D STR CONG#5 REG VALVE 52BAR REG-SS 15 D STR CONG#6 REG VALVE 52BAR REG-SS 15 D STR CONG#7 REG VALVE 52BAR REG-SS 20 D ANG CONG#4 REG VALVE 52BAR REG-SS 20 D ANG CONG#5 REG VALVE 52BAR REG-SS 20 D ANG CONG#6 REG VALVE 52BAR REG-SS 20 D ANG CONG#7 REG VALVE 52BAR REG-SS 20 D STR CONG#4 REG VALVE 52BAR REG-SS 20 D STR CONG#5 REG VALVE 52BAR REG-SS 20 D STR CONG#6 REG VALVE 52BAR REG-SS 20 D STR CONG#7 REG VALVE 52BAR REG-SS 25 D ANG CONG#4 REG VALVE 52BAR REG-SS 25 D ANG CONG#5 REG VALVE 52BAR REG-SS 25 D ANG CONG#6 REG VALVE 52BAR REG-SS 25 D ANG CONG#7 REG VALVE 52BAR REG-SS 25 D STR CONG#4 REG VALVE 52BAR REG-SS 25 D STR CONG#5 REG VALVE 52BAR REG-SS 25 D STR CONG#6 REG VALVE 52BAR REG-SS 25 D STR CONG#7 REG VALVE 52BAR REG-SS 32 D ANG CONG#10 REG VALVE 52BAR REG-SS 32 D ANG CONG#8 REG VALVE 52BAR REG-SS 32 D ANG CONG#9 REG VALVE 52BAR REG-SS 32 D STR CONG#10 REG VALVE 52BAR REG-SS 32 D STR CONG#8 REG VALVE 52BAR REG-SS 32 D STR CONG#9 REG VALVE 52BAR REG-SS 40 D ANG CONG#10 REG VALVE 52BAR REG-SS 40 D ANG CONG#8 REG VALVE 52BAR REG-SS 40 D ANG CONG#9 REG VALVE 52BAR REG-SS 40 D STR CONG#10 REG VALVE 52BAR REG-SS 40 D STR CONG#8 REG VALVE 52BAR REG-</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=19</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=19</link><title>RA Page 19</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Ordering (cont.) Stop check valve (stainless steel) Size mm 15 20 25 32 40 in. 1 3 Type /2 /4 SCA-SS 15 D ANG STOP/CHECK VALVE 52BAR SCA-SS 20 D ANG STOP/CHECK VALVE 52BAR SCA-SS 25 D ANG STOP/CHECK VALVE 52BAR SCA-SS 32 D ANG STOP/CHECK VALVE 52BAR SCA-SS 40 D ANG STOP/CHECK VALVE 52BAR Max. Working Pressure 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) Connection DIN DIN DIN DIN DIN Code Number 148G3532 148G3533 148G3534 148G3535 148G3536 1 13/4 11/2 Check valve (stainless steel) Size mm 15 20 25 32 40 in. 1 3 Type /2 /4 CHV-SS 15 D ANG CHECK VALVE 52BAR CHV-SS 20 D ANG CHECK VALVE 52BAR CHV-SS 25 D ANG CHECK VALVE 52BAR CHV-SS 32 D ANG CHECK VALVE 52BAR CHV-SS 40 D ANG CHECK VALVE 52BAR Max. Working Pressure 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) Connection DIN DIN DIN DIN DIN Code Number 148G3537 148G3538 148G3539 148G3540 148G3541 1 13/4 11/2 Filter (stainless steel) Size mm 15 15 20 20 25 25 32 32 40 40 50 50 65 65 in. 1 1 3 3 Type /2 /2 /4 /4 FIA-SS 15 D ANG FILTER HOUSING 52BAR FIA-SS 15 D STR FILTER HOUSING 52BAR FIA-SS 20 D ANG FILTER HOUSING 52BAR FIA-SS 20 D STR FILTER HOUSING 52BAR FIA-SS 25 D ANG FILTER HOUSING 52BAR FIA-SS 25 D STR FILTER HOUSING 52BAR FIA-SS 32 D ANG FILTER HOUSING 52BAR FIA-SS 32 D STR FILTER HOUSING 52BAR FIA-SS 40 D ANG FILTER HOUSING 52BAR FIA-SS 40 D STR FILTER HOUSING 52BAR FIA-SS 50 D ANG FILTER HOUSING 52BAR FIA-SS 50 D STR FILTER HOUSING 52BAR FIA-SS 65 D ANG FILTER HOUSING 52BAR FIA-SS 65 D STR FILTER HOUSING 52BAR Max. Working Pressure 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) Connection DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN Code Number 148H3221 148H3285 148H3222 148H3286 148H3223 148H3287 148H3224 148H3288 148H3225 148H3289 148H3283 148H3290 148H3284 148H3291 1 1 13/4 13/4 11/2 11/2 2 2 21/2 21/2 Overflow valve (stainless steel) Size mm 20 25 in. 3 Type /4 OFV-SS 20 D ANG OVER FLOW VALVE 52BAR OFV-SS 25 D ANG OVER FLOW VALVE 52BAR Max. Working Pressure 52 bar (754 psi) 52 bar (754 psi) Connection DIN DIN Code Number 148G3194 148G3195 1 Differential pressure can be adjusted 2-8 bar D = Butt weld DIN connection STR = Straightway ANG = Angleway  Danfoss A/S (RA Marketing/MWA), 08 - 2007 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243 19</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=20</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=20</link><title>RA Page 20</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Ordering (cont.) Hot gas defrost using ICS with CVP (XP) ICS 25 - Ordering complete factory assembled valve (body, function module and top cover) Available connections 20 D (3/4 in.) 25 D (1 in.) 32 D (11/4 in.) 40 D (11/2 in.) 13/8in. SA (35) 11/8 in. SA 7 8 / in. SA 28 SD ICS 25-5 ICS 25-10 1 pilot 3 pilots ICS 25-15 1 Pilot 3 Pilots 1 Pilot 3 Pilots 1 Pilot 3 Pilots 027H2028 027H2078 027H2038 027H2088 027H2048 027H2098 22 SD 027H2020 027H2070 027H2030 027H2080 027H2040 027H2090 3 4 027H2026 027H2076 027H2036 027H2086 027H2046 027H2096 1 in. A (25) 11/4 in. A (32) 3 4 027H2025 027H2075 027H2035 027H2085 027H2045 027H2095 3 4 027H2024 027H2074 027H2034 027H2084 027H2044 027H2094 1 in. FPT / in. A (20) / in.SOC (20) 1 in. SOC (25) / in. FPT ICS 25-5 ICS 25-10 ICS 25-15 1 Pilot 3 Pilots 1 Pilot 3 Pilots 1 Pilot 3 Pilots 027H2023 027H2073 027H2033 027H2083 027H2043 027H2093 027H2029 027H2079 027H2039 027H2089 027H2049 027H2099 027H2021 027H2071 027H2031 027H2081 027H2041 027H2091 027H2140 027H2145 027H2141 027H2146 027H2142 027H2147 Select from parts programme (see the technical leaflet RD4YA) Pilot Type CVPP (HP) CVP (XP) CVC-HP (4-25 bar regulating range) CVPP (HP) CVP (XP) EVM (NC) EVM (NC) Max. Working Pressure 40 bar (580 psi) 52 bar (754 psi) 40 bar (580 psi) 65 bar (942 psi) Code Number 027B1268 027B0080 027B0087 032F8011 Solenoid valve stainless steel Size Type mm in 3/ 10 EVRS 3 8 1/ 15 EVRST 10 with manual stem 2 3/ 20 EVRST 15 with manual stem 4 25 1 EVRST 20 with manual stem Coils: See “Coils for Solenoid valves” Max. Working Pressure 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) 52 bar (754 psi) Connection DIN DIN DIN DIN Code number 032X3080 032X3083 032X3085 032X2237 Coils A.C. coils 110 V a.c. 20 W, 50 Hz with terminal box 24 V a.c. 20 W, 50 Hz with terminal box 230 V a.c., 20W, 50 Hz Code no. 018Z6904 018F6901 018F6905 ICM - special valves ICM are used in many CO2 applications with a high pressure difference, therefore Danfoss now offers dedicated optimized ICM function modules for CO2 applications. Type ICM 20-A CO2 Module ICM 20-B CO2 Module ICM 20-C CO2 Module ICM 25-A CO2 Module ICM 25-B CO2 Module ICM 32-A CO2 Module ICM 32-B CO2 Module ICM 40-A CO2 Module ICM 40-B CO2 Module ICM 50-A CO2 Module ICM 50-B CO2 Module ICM 65-B CO2 Module Code Number 027H1183 027H1184 027H1185 027H2183 027H2184 027H3183 027H3184 027H4183 027H4184 027H5183 027H5184 027H6184 Please note: The ICM CO2 solution is only available as ICM function modules. ICV valve body and actuator type ICAD 600 / 900 must be ordered separately. 20 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243  Danfoss A/S (RA Marketing/MWA), 08 - 2007</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=21</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=21</link><title>RA Page 21</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications Ordering (cont.) DCR housings + top cover Type DCR 0487 DCR 0489 DCR0489 DCR 04811 DCR 04813 DCR 04817 DCR 0967 DCR 0969 DCR 09611 DCR 09613 DCR 09617 2 1 3/8 1 5/8 2 1/8 54 1 1 1/8 1 3/8 1 5/8 2 1/8 7 8 Number of cores High-pressure steel connectors Solder ODF in. 7 8 Butt weld ODF mm 22 28 35 54 22 28 35 in. 3 4 Code no. 023U7451 023U7452 023U7453 023U7454 023U7455 023U7457 023U7458 023U7459 023U7461 023U7462 023U7464 Max. working pressure (PS/MWP) / / 1 1 1 1/4 1 1/2 2 3 4 46 bar / / 1 1 1/4 1 1/2 2 46 bar DCR inserts Code no. Type 48-DM solid core 48-DC solid core 48-DA solid core 48-F strainer Material with gasket 100% molecular sieve 80% molecular sieve &amp;amp; 20% Al3O2 30% molecular sieve &amp;amp; 70% Al3O2 023U1392 023U4381 023U5381 023U1921 8 pcs. without gasket 023U1393 023U4382 023U5382 1 piece with gasket 023U1391 023U4380 023U5380 Core surface DM 048, DC 048 and DA 048 DM 096, DC 096 and DA 096 DM 144, DC 144 and DA 144 DM 192, DC 192 and DA 192 48-F = = = = = 435 cm2 870 cm2 1305 cm2 1740 cm2 405 cm2 Core volume DM 048, DC 048 and DA 048 DM 096, DC 096 and DA 096 DM 144, DC 144 and DA 144 DM 192, DC 192 and DA 192 = = = = 760 cm3 1520 cm3 2280 cm3 3040 cm3 Pressure transmitter Type AKS 3000 AKS 3000 Pressure range PE 0.60 BAR PE 0.60 BAR Electrical connection DIN 43650-A, PLUG PG9 DIN 43650-A, PLUG PG9 Pressure connection 1/4-18 NPT G1/2 EN 837 Code no. 060G1083 060G3631 Delivery Please note: The high pressure specials are generally available but extended delivery times should be considered.  Danfoss A/S (RA Marketing/MWA), 08 - 2007 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243 21</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=22</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=22</link><title>RA Page 22</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications 22 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243  Danfoss A/S (RA Marketing/MWA), 08 - 2007</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=23</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=23</link><title>RA Page 23</title><description>Application guide Industrial Refrigeration Valves for CO2 Applications  Danfoss A/S (RA Marketing/MWA), 08 - 2007 RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243 23</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=24</guid><link>http://danfoss.ipapercms.dk/refrigerationandairconditioning/RA/DanfossIndustrialRefrigeration/ComponentsCO2Applications/?Page=24</link><title>RA Page 24</title><description>The Danfoss product range for the refrigeration and air conditioning industry Danfoss Refrigeration &amp;amp; Air Conditioning is a worldwide manufacturer with a leading position in industrial, commercial and supermarket refrigeration as well as air conditioning and climate solutions. We focus on our core business of making quality products, components and systems that enhance performance and reduce total life cycle costs – the key to major savings. Controls for Controls for Commercial Refrigeration Industrial Refrigeration Electronic Controls &amp;amp; Sensors Industrial Automation Household Compressors Commercial Compressors Sub-Assemblies Thermostats We are offering a single source for one of the widest ranges of innovative refrigeration and air conditioning components and systems in the world. And, we back technical solutions with business solution to help your company reduce costs, streamline processes and achieve your business goals. Danfoss A/S • www.danfoss.com RA0XA502 → DKRCI.PA.000.D1.02 / 520H0243 Produced by Danfoss RA Marketing, MWA. 06-2007</description><a10:updated>2008-05-09T08:01:43+02:00</a10:updated></item></channel></rss>