Contact Details Danfoss Randall Ltd Ampthill Road Bedford MK42 9ER Reception Tel: Fax: UK Sales Tel: Fax: Training Tel: Fax: Lit
Tim eC ont rols Contents Popular Products Danfoss Randall Website Radiator Thermostats 4 5 6-19 Valv es Underfloor Hea ting Unde
Back to Contents Page Popular Products Overview Domestic Radiator Thermostats Product Code No. RAS-C2 15mm 013G605000 RAS-C2 8/1
Back to Contents Page www.danfoss-randall.co.uk Summary • Product search • Product specifications • Online literature search • W
Back to Contents Page Product Selector Radiator Thermostats (for use on 2-pipe systems only) Domestic TRV’s and Lockshield Valve
Back to Contents Page Radiator Thermostats Contents RAS-C2 Domestic TRV RAS-D2 Domestic TRV RA2000 Commercial TRV RA-Plus Progra
Back to Contents Page RAS-C2 Domestic Radiator Thermostat The compact RAS-C2 is equally suited to both the domestic and contract
Back to Contents Page RAS-D2 Domestic Radiator Thermostat The RAS-D2 range complements the one-off market with its modern, stylis
Back to Contents Page RA2000 Commercial Radiator Thermostat For the commercial market, Danfoss offers a range of valves and senso
Back to Contents Page RA-Plus Programmable Radiator Thermostat The RA-Plus combines the simplicity and reliability of a radiator
Back to Contents Page RA-FN & RA-G Valve Bodies Without Pre-Setting The choice and variety of radiator thermostat valve bodies a
Back to Contents Page RA-N Valve Bodies With Pre-Setting RA-N radiator thermostat valve bodies are designed to assist balancing
Back to Contents Page RLV-D Domestic Lockshield Valves The range of domestic lockshield valves are engineered to extremely high
Back to Contents Page RLV Commercial Lockshield Valves The RLV range of lockshield valves provides a matching return mounted loc
Back to Contents Page H-Pieces & Sensors for Built-In Valves Special add-on components for valve radiators where the need for co
Back to Contents Page Bathroom Solutions Designer radiators and bathroom towel rails are growth areas in the heating market. Dan
Back to Contents Page Replacement Sensors Gland Seal & Accessories As part of their commitment to service, Danfoss produces a ra
Back to Contents Page Compression Fittings for Copper, PEX & ALUPEX Pipe To support the range of radiator thermostats, Danfoss o
Back to Contents Page Product Selector Time Controls Domestic Timeswitches Electronic 24 Hour TS715 Si 103E5 SET1E ElectroMechan
Back to Contents Page Time Controls Contents 22 23 24 25 26 27 28 TS715 Si, CP715 Si & FP715 Si Time Controls FP975 Replacement
Back to Contents Page MK18 Time Controls With Service Interval For use in any domestic heating and hot water function. The MK18
Back to Contents Page FP975 Replacement Time Control A convenient upgrade from MK9, SET5 or any model using British Gas standard
Back to Contents Page GP Timeswitches Ideal for systems where heating and domestic hot water are required at the same time or th
Back to Contents Page GP Mini-Programmers Ideal for control systems where heating and domestic hot water are required at the sam
Back to Contents Page SET Time Controls For situations where simplicity of control is paramount. Summary • Easy to operate • 24
Back to Contents Page MK3 Programmers For situations where simplicity of control is paramount. A range of basic electro-mechanic
Back to Contents Page MK8 Commercial Time Controls Commercial time and bell-ringing controls Summary • 7 day operation • 200 eve
Back to Contents Page Notes www.danfoss-randall.co.uk 29
Back to Contents Page Product Selector Electric Thermostats Dial Setting Room Thermostats for Heating Applications Electro-mecha
Back to Contents Page Electric Thermostats Contents 32 33 34 35 36 37 38 39 40 TP4000 Room Thermostat TP5000 Si Room Thermostat
Back to Contents Page TP4000 24 Hour Programmable Room Thermostat Easy to use programmable thermostat providing different tempera
Back to Contents Page TP5000 Si 24 Hour or 5/2 Day Programmable Room Thermostats Programmable thermostats provide di erent tempe
Back to Contents Page TP7000 7 Day or 5/2 Day Programmable Room Thermostat For situations where a higher flexibility of control
Back to Contents Page TP9000 Programmable Room Thermostat with Hot Water The TP9000 programmable room thermostat includes an ext
Back to Contents Page RT Day/Night Set-Back Thermostats Easy to use programmable thermostats, providing different temperatures at
Back to Contents Page Radio Frequency Controlled Thermostat Systems Ideal for use in situations where it is impractical to run w
Back to Contents Page WP75-RF Hot Water Programmable Thermostat For use in domestic hot water applications Summary • Provides up
Back to Contents Page 6000 Series - Heat/Cool Programmable Thermostats A heat/cool fan-coil thermostat, ideal for use in commerc
Back to Contents Page RMT & RET Room Thermostats with Setting Dial Providing accurate and reliable temperature control for a wid
Back to Contents Page RET-B Battery Powered Room Thermostat with Setting Dial Traditional room thermostat with added functionali
Back to Contents Page RET-MD Room Thermostat Delay Start With Setting Dial Intelligent room thermostat with added functionality,
Back to Contents Page RET Room Thermostats with Setting Dial & Function Switches Suitable for the commercial heating and air con
Back to Contents Page FlatStat FMT230D Flush Mounted Thermostat Stylish, flush mount room thermostat with LED output indicator a
Back to Contents Page RET Heat/Cool Room Thermostats Flexible, versatile heat/cool room thermostats with many enhanced features.
Back to Contents Page ORT Modulating Thermostats for use with OpenTherm Boilers OpenTherm controls providing modulating control
Back to Contents Page Cylinder, Pipe and Frost Thermostats For a wide range of applications including control of hot water cylin
Back to Contents Page Immersion Thermostats Used for control and limitation of water temperature in the hot water cylinder and o
Back to Contents Page Chrono-Proportional Controls Reduce energy costs and carbon emissions - Fit chrono-proportional controls I
Back to Contents Page Product Selector Underfloor Heating Controls Electric Underfloor Heating: Floor Warming Mats Concrete floo
Back to Contents Page Underfloor Heating Contents 52 Devimat electric underfloor heating systems 53 Devimat electric underfloor
Back to Contents Page Electric Underfloor Heating Ideal for small floor heating requirements in bathrooms, kitchens or conservat
Back to Contents Page Electric Underfloor Heating Installation Information 1. The free area where the floor heating is to be fit
Back to Contents Page FH-WC Hard Wired Zone Control A system for use with hard-wired thermostats, providing structured wiring an
Back to Contents Page FH-BU Wireless Zone Control Wireless thermostat systems offer significant installation cost advantages as t
Back to Contents Page CFD Manifolds & TWA Actuators Our manifolds and thermal actuators are developed to fulfil underfloor heati
Back to Contents Page FHV-R Underfloor Heating Valve Small floor heating systems in conservatories, kitchens or bathrooms. For s
Back to Contents Page Product Selector Motorised Valves & Other Controls Control Packs Hard-Wired 2-Port Heatplan Wireless 2-Por
Back to Contents Page Motorised Valves & Other Controls Contents 60 Hard-Wired Control Packs and Wiring Centres 61 Wireless Cont
Back to Contents Page Hard Wired Control Packs & Wiring Centres Competitively priced for the contracts market, Danfoss Controls
Back to Contents Page Wireless Controls Packs A new concept in domestic heating controls aimed at ‘speeding-up’ the installation
Back to Contents Page H-Series Motorised Valves Paddle Type Central heating and hot water circulation in wet domestic central he
Back to Contents Page H-Series Motorised Valves Shoe Type Central heating and hot water circulation in wet domestic central heat
Back to Contents Page Domestic Automatic Bypass Valves Automatic bypass valves for use in domestic heating systems. Summary • Ea
Back to Contents Page RAV/VMT/KOVM/VMV Small Seated Valves Small seated valves are used with a wide range of self-acting tempera
Back to Contents Page Thermal Actuators Electrical control of radiators, heating zones and hot water service control, where othe
Back to Contents Page RAVI Thermostatic Cylinder Controls Ideal for system upgrade situations where consumers want the benefits
Back to Contents Page AVPL Differential Pressure Controls for District Heating Consumer Units AVPL differential pressure controls
Back to Contents Page Additional Information Contents 70 Wallplate Information 71 Wiring Information 77 Schematic - Combi Boiler
Back to Contents Page Wallplate Identification and Compatibility GP Wallplate MK18 Wallplate Timeswitches 103 103E5 103E7 1 ON 2
Back to Contents Page Wiring Diagrams 1 102, 102E5, 102E7 103, 103E5, 103E7 ELECTRONICS COM N/O TIMER SET1E COM N/O TIMER N/O N/
Back to Contents Page Wiring Diagrams 2 RMT230* RMT230 RMT230T T Rn T T RP RP 230V supply RMT230 star (3052 12/01) 1 3 2 COM OFF
Back to Contents Page Wiring Diagrams 3 RET230C02 RET230C03 SW1 I RL 0 0 SW1 ELECTRONICS SW2 > ELECTRONICS RL I II > SW2 III N L
Back to Contents Page Wiring Diagrams 4 HPA2 HC6110-3 and HC6113-3 M ELECTRONICS BROWN (L) GREY ORANGE BLUE (N) 230 Volt COOL HE
Back to Contents Page Wiring Diagrams 5 ATC ATP ATF 3 2 1 OFF ON COM NO CO NC ON COM OFF 2 1 4 ON COM OFF ITC ELECTRONICS 811, 8
Back to Contents Page Wiring Diagrams 6 FH-BU Wireless Receiver Unit & Wiring Centre DEVIREG 550 DEVIREG 130 5 - 45°C Max 16A L
Back to Contents Page Combi Boiler System Programmable Room Thermostat (see pages 32-34) Automatic Bypass Valve (see page 64) Ra
Back to Contents Page Mid Position Valve System Mid-position Valve (see pages 62-63) Wiring Box (see page 60) Cylinder Thermosta
Back to Contents Page Two Port Zone Valve System Heating & DHW Zone Valve (see pages 62-63) Wiring Box (see page 60) Cylinder Th
Back to Contents Page Two Port Zone Valve System with Additional Heating Zone DHW Zone Valve (see pages 62-63) Wiring Box (see p
Back to Contents Page Radio Frequency (RF) Control Packs & Wiring Wiring Information 3 Port Permanent links Links to be made by
Back to Contents Page Hard Wired Underfloor Heating System FH-WC Wiring Centre (see page 54) RAVK Sensor (see page 67) VMV Mixin
Back to Contents Page Wireless Underfloor Heating System FH-BU Wiring Centre (see page 55) Room Thermostat (1 per circuit) (see
Back to Contents Page Radiator Thermostat Selection and Cross Reference Chart START Size Code No. Description - RAS-D2 Flow sele
Back to Contents Page Commercial Radiator Thermostat Selection Guide • Approved combination, refer to notes for any restrictions
Back to Contents Page Building Regulations Summary New System Controls required by Part L (England and Wales) Part J (Scotland)
Back to Contents Page Literature Service Product Range Product Selection Guide Wireless Control Packs Underfloor Heating Product
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves t
Page 1:
EVER INCREASING INNOVATIO
Page 2:
Contact Details Danfoss Randall Ltd Ampthill Road Bedford MK42 9
Page 3:
Tim eC ont rols Contents Popular Products Danfoss Randall Websit
Page 4:
Back to Contents Page Popular Products Overview Domestic Radiato
Page 5:
Back to Contents Page www.danfoss-randall.co.uk Summary • Produc
Page 6:
Back to Contents Page Product Selector Radiator Thermostats (for
Page 7:
Back to Contents Page Radiator Thermostats Contents RAS-C2 Domes
Page 8:
Back to Contents Page RAS-C2 Domestic Radiator Thermostat The co
Page 9:
Back to Contents Page RAS-D2 Domestic Radiator Thermostat The RA
Page 10:
Back to Contents Page RA2000 Commercial Radiator Thermostat For
Page 11:
Back to Contents Page RA-Plus Programmable Radiator Thermostat T
Page 12:
Back to Contents Page RA-FN & RA-G Valve Bodies Without Pre-Sett
Page 13:
Back to Contents Page RA-N Valve Bodies With Pre-Setting RA-N ra
Page 14:
Back to Contents Page RLV-D Domestic Lockshield Valves The range
Page 15:
Back to Contents Page RLV Commercial Lockshield Valves The RLV r
Page 16:
Back to Contents Page H-Pieces & Sensors for Built-In Valves Spe
Page 17:
Back to Contents Page Bathroom Solutions Designer radiators and
Page 18:
Back to Contents Page Replacement Sensors Gland Seal & Accessori
Page 19:
Back to Contents Page Compression Fittings for Copper, PEX & ALU
Page 20:
Back to Contents Page Product Selector Time Controls Domestic Ti
Page 21:
Back to Contents Page Time Controls Contents 22 23 24 25 26 27 2
Page 22:
Back to Contents Page MK18 Time Controls With Service Interval F
Page 23:
Back to Contents Page FP975 Replacement Time Control A convenien
Page 24:
Back to Contents Page GP Timeswitches Ideal for systems where he
Page 25:
Back to Contents Page GP Mini-Programmers Ideal for control syst
Page 26:
Back to Contents Page SET Time Controls For situations where sim
Page 27:
Back to Contents Page MK3 Programmers For situations where simpl
Page 28:
Back to Contents Page MK8 Commercial Time Controls Commercial ti
Page 29:
Back to Contents Page Notes
Page 30:
Back to Contents Page Product Selector Electric Thermostats Dial
Page 31:
Back to Contents Page Electric Thermostats Contents 32 33 34 35
Page 32:
Back to Contents Page TP4000 24 Hour Programmable Room Thermosta
Page 33:
Back to Contents Page TP5000 Si 24 Hour or 5/2 Day Programmable
Page 34:
Back to Contents Page TP7000 7 Day or 5/2 Day Programmable Room
Page 35:
Back to Contents Page TP9000 Programmable Room Thermostat with H
Page 36:
Back to Contents Page RT Day/Night Set-Back Thermostats Easy to
Page 37:
Back to Contents Page Radio Frequency Controlled Thermostat Syst
Page 38:
Back to Contents Page WP75-RF Hot Water Programmable Thermostat
Page 39:
Back to Contents Page 6000 Series - Heat/Cool Programmable Therm
Page 40:
Back to Contents Page RMT & RET Room Thermostats with Setting Di
Page 41:
Back to Contents Page RET-B Battery Powered Room Thermostat with
Page 42:
Back to Contents Page RET-MD Room Thermostat Delay Start With Se
Page 43:
Back to Contents Page RET Room Thermostats with Setting Dial & F
Page 44:
Back to Contents Page FlatStat FMT230D Flush Mounted Thermostat
Page 45:
Back to Contents Page RET Heat/Cool Room Thermostats Flexible, v
Page 46:
Back to Contents Page ORT Modulating Thermostats for use with Op
Page 47:
Back to Contents Page Cylinder, Pipe and Frost Thermostats For a
Page 48:
Back to Contents Page Immersion Thermostats Used for control and
Page 49:
Back to Contents Page Chrono-Proportional Controls Reduce energy
Page 50:
Back to Contents Page Product Selector Underfloor Heating Contro
Page 51:
Back to Contents Page Underfloor Heating Contents 52 Devimat ele
Page 52:
Back to Contents Page Electric Underfloor Heating Ideal for smal
Page 53:
Back to Contents Page Electric Underfloor Heating Installation I
Page 54:
Back to Contents Page FH-WC Hard Wired Zone Control A system for
Page 55:
Back to Contents Page FH-BU Wireless Zone Control Wireless therm
Page 56:
Back to Contents Page CFD Manifolds & TWA Actuators Our manifold
Page 57:
Back to Contents Page FHV-R Underfloor Heating Valve Small floor
Page 58:
Back to Contents Page Product Selector Motorised Valves & Other
Page 59:
Back to Contents Page Motorised Valves & Other Controls Contents
Page 60:
Back to Contents Page Hard Wired Control Packs & Wiring Centres
Page 61:
Back to Contents Page Wireless Controls Packs A new concept in d
Page 62:
Back to Contents Page H-Series Motorised Valves Paddle Type Cent
Page 63:
Back to Contents Page H-Series Motorised Valves Shoe Type Centra
Page 64:
Back to Contents Page Domestic Automatic Bypass Valves Automatic
Page 65:
Back to Contents Page RAV/VMT/KOVM/VMV Small Seated Valves Small
Page 66:
Back to Contents Page Thermal Actuators Electrical control of ra
Page 67:
Back to Contents Page RAVI Thermostatic Cylinder Controls Ideal
Page 68:
Back to Contents Page AVPL Differential Pressure Controls for Di
Page 69:
Back to Contents Page Additional Information Contents 70 Wallpla
Page 70:
Back to Contents Page Wallplate Identification and Compatibility
Page 71:
Back to Contents Page Wiring Diagrams 1 102, 102E5, 102E7 103, 1
Page 72:
Back to Contents Page Wiring Diagrams 2 RMT230* RMT230 RMT230T T
Page 73:
Back to Contents Page Wiring Diagrams 3 RET230C02 RET230C03 SW1
Page 74:
Back to Contents Page Wiring Diagrams 4 HPA2 HC6110-3 and HC6113
Page 75:
Back to Contents Page Wiring Diagrams 5 ATC ATP ATF 3 2 1 OFF ON
Page 76:
Back to Contents Page Wiring Diagrams 6 FH-BU Wireless Receiver
Page 77:
Back to Contents Page Combi Boiler System Programmable Room Ther
Page 78:
Back to Contents Page Mid Position Valve System Mid-position Val
Page 79:
Back to Contents Page Two Port Zone Valve System Heating & DHW Z
Page 80:
Back to Contents Page Two Port Zone Valve System with Additional
Page 81:
Back to Contents Page Radio Frequency (RF) Control Packs & Wirin
Page 82:
Back to Contents Page Hard Wired Underfloor Heating System FH-WC
Page 83:
Back to Contents Page Wireless Underfloor Heating System FH-BU W
Page 84:
Back to Contents Page Radiator Thermostat Selection and Cross Re
Page 85:
Back to Contents Page Commercial Radiator Thermostat Selection G
Page 86:
Back to Contents Page Building Regulations Summary New System Co
Page 87:
Back to Contents Page Literature Service Product Range Product S
Page 88:
Danfoss can accept no responsibility for possible errors in cata
Product Selection Guide 2008
Click here to download the catalog as a PDF file.
To view this site you need Adobe Flash Player and your browser must allow javaScripts.
Go here to get the latest Flash Player.