<?xml version="1.0" encoding="utf-16"?><rss xmlns:a10="http://www.w3.org/2005/Atom" version="2.0"><channel><title>Danfoss Heating</title><link>http://danfoss.ipapercms.dk/Heating/AutoGen/22109_22371/RSS.ashx</link><description>Danfoss Heating Pages</description><lastBuildDate>Fri, 31 Jul 2009 14:48:27 +0200</lastBuildDate><a10:id>http://danfoss.ipapercms.dk/Heating/AutoGen/22109_22371/</a10:id><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Heating/AutoGen/22109_22371/?Page=1</guid><link>http://danfoss.ipapercms.dk/Heating/AutoGen/22109_22371/?Page=1</link><title>Danfoss Heating Page 1</title><description>MAKING MODERN LIVING POSSIBLE Danfoss Heat Pump DHP-AX Our most flexible and affordable air heat pump ever. Reduce your heating costs with our most affordable heat pump ever. In DHP-AX we have used our accumulated heating knowledge to develop a flexible air/water heat pump that operates at high performance. Energy is taken from outdoor air, even down to temperatures as low as –16&amp;#176;C. DHP-AX can be combined with an existing heating system, or parts of it, for example a water heater. If you need a complete solution, you can easily supplement DHP-AX with the parts you need – your installer can offer a specially adapted indoor kit to obtain maximum efficiency. The flexible DHP-AX will suit your needs, however big or small they are, and you’ll never invest in more than you need. The DHP-AX consists of only two major units, the outdoor heat pump and the indoor control unit, which makes installation quick and smooth. And since the compressor is located on the outside there are no components that can creates noise on the inside, while the sound created on the outside is at a very low level. DANFOSS HEAT PUMPS</description><a10:updated>2009-07-31T14:48:27+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Heating/AutoGen/22109_22371/?Page=2</guid><link>http://danfoss.ipapercms.dk/Heating/AutoGen/22109_22371/?Page=2</link><title>Danfoss Heating Page 2</title><description>DANFOSS DHP-AX 2 4 Connection The stand shown in the image is an accessory. 1 Supply line heating system, AX 6, 8, 10: 22 Cu, AX 12: 28 Cu 2 Return line heating system, AX 6, 8, 10: 22 Cu, AX 12: 28 Cu Components The component image below shows diagrammatically how the heat pump looks inside. There may be differences between different versions. 677 677 1 2 3 4 5 6 7 2 Fan 1 Operating pressostat High pressure pressostat Low pressure pressostat 2-way expansion valve Drying filter Compressor 4 8 9 8 9 10 11 12 13 Air heat exchanger Electrical cabinet 3 Condenser 7 Four way valve Heating system supply line Return line heating system 6 495 76 495 1193 76 1193 10 5 11 405 405 773 773 602 243 243 325 325 12 2 1 1160 1160 1 3 7 6 12 13 Indoor unit 602 380 8 9 10 5 11 212 205 380 DHP-AX Refrigerant Type Amount Test pressure Design pressure Type Oil Main supply Rated power, compressor Start current Circuit breaker Main supply Rated power, compressor Start current Circuit breaker Heat factor COP1 Heat factor COP2 Heating capacity2 Cooling circuit Heating circuit Volt kW A A Volt kW A A kg MPa MPa 212 205 6 R407C 1.6 3.2 3.1 Scroll POE 400 2.0 16 10 230 3.3 56 20 4.37 3.81 6.2 0.2 0.3 –16 60 0.03 2.85 3.10 890 3667 67.7 10/45/41 180 59.7 47.7 41.7 35.6 108 8 R407C 1.6 3.2 3.1 Scroll POE 400 2.3 17 10 230 4.2 76 20 4.47 3.99 7.9 0.3 0.4 –16 60 0.03 2.85 3.10 890 3667 67.8 7/45/40 180 59.8 47.8 41.8 35.7 113 10 R407C 2.5 3.2 3.1 Scroll POE 400 3.6 22 16 230 5.4 97 25 4.47 4.05 10.2 0.6 0.5 –16 60 0.03 2.85 3.10 890 3667 68.1 6/45/40 180 60.1 48.1 42.1 36.0 123 12 R407C 2.5 3.2 3.1 Scroll POE 400 4.4 22 16 230 5.7 108 32 4.26 3.81 11.2 0.5 0.5 –16 60 0.03 2.85 3.10 940 4045 70.4 10/45/40 250 62.0 50.0 44.0 38.0 140 Compressor Electrical data 3-N Electrical data 1-N Performance kW l/s l/s &amp;#176;C Nominal flow 3 Lowest outdoor temperature allowed for compressor start Max temperature 4 Heating circuit Low pressure Operating High pressure Nominal, free-blowing &amp;#176;C MPa MPa MPa rpm m /h 3 Pressure switches Fan speed outdoor unit, low/high Air flow Sound power level (ISO 3741) Operating temperatures for sound Fan input Sound pressure level away from outdoor unit 5 dB (A) (1 pW) Air/rad out/rad in Nominal, free-blowing 1m 4m 8m 16 m &amp;#176;C W dB (A) dB (A) dB (A) dB (A) kg Weight, heat pump 1) At A7/W35 ∆ 10K warm side (excluding circulation pumps). 2) At A7/W35 according to EN14511. 3) Heating circuit ∆ 10K, cooling circuit ∆ 3K. 4) At an outdoor temperature from 0&amp;#176;C and more. 5) Sound pressure calculated by assuming semi-spherical propagation from point source. Danfoss assumes no responsibility for any errors found in the catalogues, brochures and any other printed material. Danfoss retains the right to make changes to their products, including products that have already been ordered, without prior notice, as long as these changes can be carried out without changing predetermined specifications. All trademarks in this material belong to respective companies. Danfoss and the Danfoss logo are trademarks that belong to Danfoss A/S. All rights reserved. DHP-AX/July 2009</description><a10:updated>2009-07-31T14:48:27+02:00</a10:updated></item></channel></rss>