<?xml version="1.0" encoding="utf-16"?><rss xmlns:a10="http://www.w3.org/2005/Atom" version="2.0"><channel><title>Danfoss Drives</title><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/UK/690V/RSS.ashx</link><description>Danfoss Drives Pages</description><lastBuildDate>Fri, 23 Nov 2012 11:04:02 +0100</lastBuildDate><a10:id>http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/UK/690V/</a10:id><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/UK/690V/?Page=1</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/UK/690V/?Page=1</link><title>Danfoss Drives Page 1</title><description>MAKING MODERN LIVING POSSIBLE VLT® drives for 690 V now available down to smallest power sizes Danfoss makes 690 V installations most cost efficient. The high performance frequency converters now cover the complete 690 V power range from 1.4 MW down to 1.1 kW. Danfoss presents the smallest 690 V enclosure on the market below 7.5 kW and extends the power range of its IP 20 drives up to 75 kW with 4 new enclosure sizes. Now you can even control 690 V motors down to 0.37 kW without expensive over-dimensioned drives or step down transformers. Built on the powerful and reliable VLT® platform, the drives offer system designers, machine builders, and end users the efficiency enhancing benefits offered by Danfoss’ single drive concept for industrial applications. Suitable for use on normal TN and IT (isolated) grids, the IP 20 protected drives are especially useful in installations within chemical, mining, water/ wastewater and marine applications. D3h C3 B4 A3 Danfoss extends the power range of its IP 20 drives up to 75 kW with 4 new enclosure sizes Feature Dedicated enclosure sizes down to 1.1 kW Operate motors down to 0.37 kW Smallest size and required space Benefit No need for large over-dimensioned drive No need for step-down transformer Cost for cabinet and installation room reduced Saves valuable panel space Maintain mains quality without external filters Provide reliable operation of the installation without additional external filters Increase lifetime and reliability in harsh environments Secure operation without derating/ over-dimensioning Matching sinusoidial or du/dt filters One drive series covers all your systems needs 65% Side-by-side mounting without derating Integrated harmonic filters (&lt;40% THDi) Integrated EMC filter (A1/EN 55011) with up to 150 m screened motor cable Class 3C3 conformal coating (IEC 60721-3-3) as standard Full performance at 50° C ambient temperature (D-frames 45° C) Danfoss output filters Complete range of 690 V drives up to 1.4 MW less cabinet space required Especially for power sizes below 7.5 kW, Danfoss offers a remarkable space reduction in comparison to other solutions. Facts about our products</description><a10:updated>2012-11-23T11:04:02+01:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/UK/690V/?Page=2</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/UK/690V/?Page=2</link><title>Danfoss Drives Page 2</title><description>VLT® AutomationDrive frequency converters can be individually configured with additional safety functions through special options and accessories. ATEX-certified thermistor input The PTB ATEX-certified PTC Thermistor option MCB 112 can be used to monitor both Ex d and Ex e motors. It is certified according to IEC 61508 for use in low demand applications to protect motors placed in Zones 1, 2, 21 and 22. The option can be used as the sole protective device of an explosion-proof motor operated by a frequency converter. Universal residual current monitoring The RCMB20/35 external fault current monitoring module reliably detects insulation faults in drives systems operating on IT or TN mains. In addition to usual protection against sudden insulation faults, this module supports Ordering numbers: Sine Wave Filters VLT® ratings kW 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 690 V Current (A) 1.6 2.2 3.2 4.5 5.5 7.5 10 13 18 22 27 34 41 52 62 83 100 @50 Hz A 4.5 Filter current rating @60 Hz A 4 @100 Hz A 3 Switching frequency kHz 4 IP 00 Part-No. IP 20/23 130B7335 130B7356 10 13 28 45 76 115 9 12 26 42 72 109 7 9 21 33 57 86 4 3 3 3 3 3 130B7289 130B3195 130B4112 130B4114 130B4116 130B4118 130B7324 130B3196 130B4113 130B4115 130B4117 130B4119 preventive maintenance by detecting gradual insulation deterioration in the equipment in advance, avoiding unexpected and expensive machine standstills. Technical data Enclosure Typical shaft output Output current 150% for 1 min (HO) 110% for 1 min (NO) 160% for 1 min (HO for A3) Output power Max input current Estimated loss at rated Efficiency Height Width maximum load [W] 44 60 88 120 160 220 300 228 285 335 375 480 592 0.98 720 1057 1204 1205 1477 1480 1798 550 308 333 35 0.98 520 230 242 23.5 Depth Max weight IP 20 P1K1 P1K5 P2K2 P3K0 P4K0 P5K5 P7K5 HO P11K NO HO P15K NO HO P18K NO HO P22K NO HO P30K NO HO P37K NO HO P45K NO HO N55K NO HO N75K NO HO N90K NO [kW] 1.1 1.5 2.2 3 4 5.5 7.5 11 15 15 18.5 18.5 22 22 30 30 37 37 45 45 55 55 75 75 90 90 110 Continuous Intermittent Continuous Continuous Intermittent (3x551-690 V) (3x551-690 V) kVA 690 V AC (3x551-690 V) (3x551-690 V) [A] [A] [kVA] [A] [A] 1.6 2.2 3.2 4.5 5.5 7.5 10 13 18 18 22 22 27 27 34 34 41 41 52 52 62 73 86 86 108 108 131 2.6 3.5 5.1 7.2 8.8 12 16 20.8 19.8 28.8 24.2 35.2 29.7 43.2 37.4 51 45.1 61.5 57.2 78 68.2 110 95 129 119 162 144 1.9 2.6 3.8 5.4 6.6 9 12 15.5 21.5 21.5 26.3 26.3 32.3 32.3 40.6 40.6 49.0 49 62.2 62.2 74.1 87 103 103 129 129 157 1.4 2.0 2.9 4.0 4.9 6.7 9.0 12.5 17.4 17.4 21.2 21.2 26.0 26.0 32.8 32.8 39.5 39.5 50.1 50.1 59.8 77.0 87.0 87.0 109.0 109.0 128.0 2.3 3.2 4.6 6.5 7.9 10.8 14.4 20.1 19.1 27.8 23.3 33.9 28.6 41.6 36.0 49.2 43.5 59.3 55.1 75.2 65.8 96.3 95.7 130.5 119.9 163.5 140.8 Of back Of back Without plate plate option [mm] [mm] A/B [mm] [kg] A3 0.96 268 130 205 6.6 B4 C3 D3h 0.98 909 250 375 62 VLT® power rating: Power ratings correspond to both HO and NO ratings. Danfoss VLT Drives, Ulsnaes 1, DK-6300 Graasten, Denmark, Tel. +45 74 88 22 22, Fax +45 74 65 25 80 www.danfoss.com/drives, E-mail: info@danfoss.com DKDD.PFP.300.A3.02 VLT® is a trademark of Danfoss A/S PE-MMSC 2012.11</description><a10:updated>2012-11-23T11:04:02+01:00</a10:updated></item></channel></rss>