<?xml version="1.0" encoding="utf-16"?><rss xmlns:a10="http://www.w3.org/2005/Atom" version="2.0"><channel><title>Danfoss Drives</title><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/02MP030Axx/RSS.ashx</link><description>Danfoss Drives Pages</description><lastBuildDate>Tue, 20 Sep 2011 14:22:56 +0200</lastBuildDate><a10:id>http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/02MP030Axx/</a10:id><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/02MP030Axx/?Page=1</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/02MP030Axx/?Page=1</link><title>Danfoss Drives Page 1</title><description>MAKINGMODERNLIVINGPOSSIBLE Next Generation D-Frame VLT® Drive Improvedperformanceinapplicationsbetween90-315kW. Customerstodayareincreasingly demanding high efficiency in drive technology. Investments in higher efficiencyquicklypayoff,especiallyat higher power levels. One of the most efficient drives in the industry has been made more efficient. The size of the new D-Frame has been reducedbyupto68%totakeupless space in control rooms and panels. AnewIP20versionisoptimizedfor panel building, while continuing to usetheprovenbackchannelcooling concept.Backchannelcoolingnow directs90%ofcoolingairawayfrom thedriveinteriorandremoves90%of the heat generated by the drive. The compact, efficient design is the result of innovative thermal management. The new D-Frame VLT requires less panel or wall space than previous models which were already some of the smallest in their class, adding Feature Reduced size installation flexibility while reducing installation costs. The new D-frame is available in the same platforms as Danfoss’ renowned VLT drives. • FC302AutomationDriveforapplications in demanding industrial applications • FC202AquaDriveforapplications in the water and wastewater applications(andotherpumpapplications) • FC102HVACDriveforapplication intheHVACandrefrigeration industries AvailableinIP20,IP21andIP54enclosures, the new drives maintain the same award winning control platform andLCPastoday’sDanfossVLTs. Power Ratings (at 400V) Voltage Ratings: FC30290kW-250kW380-500(T5) FC202110kW-315kW380-480(T4) FC102110kW-315kW380-480(T4) Benefit Reduced in size by up to 68%. The smaller NextGen D-Frame drive uses less panel space or wall space, saving space and money. Higher efficiency results in lower operating cost, reducing cost over the life of the frequency converter. Eliminates the need for a panel when only the basic input options are required, leading to further cost savings and reduced space requirements. There are no new controls to learn. The transition from the old drive to the new drive can be made easily. IP20designenhancessafety Enablestheheat-sinktobecleanedwhen installed in harsh environments Reduces the needed air conditioning for the room, reducing up-front cost and operating cost Note:ThenewD1hFrameVLTDrivetakesup significantly less space than the older version. 68% smaller footprint in selected models provides ease of installation and lower material costs. New features increase efficiency and reduce operation costs. Higher Efficiency Basic input options • Fuses • Maindisconnect • Contactor(new) • Circuitbreaker(new) • Mainsdisconnect+contactor(new) SamecontrolplatformandLCP IP20enclosureratingfordrivesbeinginstalled into enclosures Optionalheatsink-accesspanel BackChannelCoolingpermitsupto90%of cooling air to be removed from room Facts about our products</description><a10:updated>2011-09-20T14:22:56+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/02MP030Axx/?Page=2</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/02MP030Axx/?Page=2</link><title>Danfoss Drives Page 2</title><description>Back-channel cooling Auniquedesignusesaductedback channel to pass cooling air over heatsinkswithminimalairpassing through the electronics area. This allows90%oftheheatlossesto be exhausted directly outside of the enclosure, improving reliability and prolonging life by dramatically reducing temperature rise and contamination of the electronic components.ThereisanIP54seal betweentheback-channelcooling duct and the electronics area of the VLT®Drive. Power ratings (400V) FC 302 High Overload Model FC302T5N90K FC302T5N110 FC302T5N132 FC302T5N160 FC302T5N200 FC302T5N250 TypicalShaft output (kW) 90 110 132 160 200 250 Output Current (Amps) 190 240 302 361 443 535 Model FC102T4N110 FC202T4N110 FC102T4N132 FC202T4N132 FC102T4N160 FC202T4N160 FC102T4N200 FC202T4N200 FC102T4N250 FC202T4N250 FC102T4N315 FC202T4N315 FC 102/202 Normal Overload Typical Shaft Output (kW) 110 132 160 200 250 315 Output Current (Amps) 190 240 302 361 443 535 D2h/ D4h D1h/ D3h Frame Cabinet sizes Enclosure Frame Width(mm) Height(mm) Depth(mm) IP 21/IP 54 (NEMA-1/NEMA-12) D1h 325 901 378 D2h 420 1107 378 D3h 250 909 375 IP 20 (Chassis) D4h 350 1122 375 Danfoss VLT Drives,Ulsnaes1,DK-6300Graasten,Denmark,Tel.+4574882222,Fax+4574652580 Web:www.danfoss.com/drives•E-mail:info@danfoss.com MP030A02 VLT®isatrademarkofDanfossA/S ProducedbyPE-MMSC2011.09</description><a10:updated>2011-09-20T14:22:56+02:00</a10:updated></item></channel></rss>