<?xml version="1.0" encoding="utf-16"?><rss xmlns:a10="http://www.w3.org/2005/Atom" version="2.0"><channel><title>Danfoss Drives</title><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/02MP010Axx/RSS.ashx</link><description>Danfoss Drives Pages</description><lastBuildDate>Fri, 16 Sep 2011 15:05:43 +0200</lastBuildDate><a10:id>http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/02MP010Axx/</a10:id><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/02MP010Axx/?Page=1</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/02MP010Axx/?Page=1</link><title>Danfoss Drives Page 1</title><description>MAKING MODERN LIVING POSSIBLE VLT® Decentral FCD 300 The VLT® Decentral FCD 300 is a complete frequency converter designed for decentral mounting. It can be mounted on the machine or a wall close to the motor, or directly on the motor. The VLT® Decentral FCD 300 comes in very robust enclosure, with a special painting treatment to withstand harsh environments and typical cleaning agents used in wash-down areas. Its design offers a smooth cleaning-friendly surface. The decentral design reduces the need for central control panels and eliminates the need for space-consuming motor control cabinets. The need for long screened motor cables is significantly reduced. Power range 0.37 – 3.3 kW, 3 x 380 – 480 V Enclosure IP 66/Type 4X (indoor) Feature Reliable Special surface treatment as protection against aggressive environments Twin part design (installation box and electronic part) Integrated lockable service switch available Full protection is offered User-friendly Adapts to any brand of motor and geared motor Designed for power and fieldbus looping Visible LEDs Set-up and controlled through a remote control panel or fieldbus communication and dedicated MCT 10 set-up software Benefit Maximum uptime Easy cleaning; no dirt trap Easy and fast service Local disconnection possible Protects the motor and drive Saves commissioning and operating cost Easy and flexible installation Cable savings Quick status check Easy commissioning Perfect match for: – Material handling in Food &amp; – Installations in wash-down areas – Widely distributed applications Beverage Industry Facts about our products</description><a10:updated>2011-09-16T15:05:43+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/02MP010Axx/?Page=2</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SalesPromotion/Factsheets/ProductFactsheets/02MP010Axx/?Page=2</link><title>Danfoss Drives Page 2</title><description>Specifications Mains supply (L1, L2, L3) Supply voltage Supply frequency Max. imbalance on supply voltage Switching on input supply Power Factor (cos φ) Output data (U, V, W) Output voltage Overload torque Switching on output Ramp times Output frequency 3 x 380/400/415/440/480 V ± 10% 50/60 Hz ± 2.0% of rated supply voltage 2 times/min. 0.9 /1.0 at rated load 0–100% of supply 160% for 60 sec. Unlimited 0.02 - 3600 sec. 0.2 - 132 Hz, 1 - 1000 Hz 5 0–24 V DC (PNP positive logic) 2 (1 voltage, 1 current) 0– ±10 V DC / 0/4–20 mA (scaleables) 2 (24 V DC) 110 kHz (push-pull) / 5 kHz (open collector) 1 0/4–20 mA 1 24 V DC/10 kHz (max.) 1 250 V AC, 2 A, 500 VA Built-in Optional (integrated) 1.0 g (IEC 60068) 95 % (IEC 60068-2-3) Max. 40˚C (24 hour average max. 35˚C) 0˚C -10˚C CE, UL, C-tick, ATEX* Plug-and-drive The bottom section contains maintenance-free Cage Clamp connectors and looping facilities for power and fieldbus cables. Once installed, commissioning and upgrading can be performed in no time by plugging in another control lid. Digital inputs Programmable digital inputs Voltage level Analog inputs Analog inputs Voltage level/Current level Pulse inputs Programmable pulse inputs Max. frequency Analog output Programmable analog output Current range Digital output Programmable digital/frequency output Voltage/frequency level Relay output Programmable relay output Max. terminal load Fieldbus communication FC Protocol, Modbus RTU, Metasys N2 Profibus DP, DeviceNet, AS-interface Externals Vibration test Max. relative humidity Ambient temperature Min. ambient temperature in full operation Min. ambient temperature at reduced performance Approvals * Contact Danfoss for details Flexible installation The FCD 300 series facilitates internal power line and fieldbus looping. Terminals for 4 mm2 power cables inside the enclosure allows connection of up to 10+ units. Available options n n n n n n Service switch M12 connectors for external sensors Han 10E motor connector Brake chopper and resistor 24 V external back up of control and communication External electromechanical brake control and supply Technical data VLT® Decentral FCD Output current (3 x 380 – 480 V) Output power (400 V) Typical shaft output Mechanical dimensions H x W x D (mm) * tamb max. 35˚ C IINV (60s) [A] IMAX (60s) [A] SINV [KVA] PM,N [kW] PM,N [HP] Motor mounting Stand alone 303 1.4 2.2 1.0 0.37 0.5 305 307 311 1.8 2.2 3.0 2.9 3.5 4.8 1.2 1.5 2.0 0.55 0.75 1.1 0.75 1.0 1.5 244 x 192 x 142 300 x 192 x 145 315 3.7 5.9 2.6 1.5 2.0 322 330 335* 5.2 7.0 7.6 8.3 11.2 11.4 3.6 4.8 5.3 2.2 3.0 3.3 3.0 4.0 5.0 300 x 258 x 151 367 x 258 x 154 Danfoss VLT Drives, Ulsnaes 1, DK-6300 Graasten, Denmark, Tel. +45 74 88 22 22, Fax +45 74 65 25 80 www.danfoss.com/drives • E-mail: info@danfoss.com MP010A02 VLT® is a trademark of Danfoss A/S PE-MMSC 2011.08</description><a10:updated>2011-09-16T15:05:43+02:00</a10:updated></item></channel></rss>