<?xml version="1.0" encoding="utf-16"?><rss xmlns:a10="http://www.w3.org/2005/Atom" version="2.0"><channel><title>Danfoss Drives</title><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/RSS.ashx</link><description>Danfoss Drives Pages</description><lastBuildDate>Sun, 25 Oct 2009 11:50:02 +0100</lastBuildDate><a10:id>http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/</a10:id><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=1</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=1</link><title>Danfoss Drives Page 1</title><description>MAKING MODERN LIVING POSSIBLE Dedicated to HVAC business VLT&amp;#174; Drives</description><a10:updated>2009-10-25T11:50:02+01:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=2</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=2</link><title>Danfoss Drives Page 2</title><description>Eﬀective HVAC solutions From the world&amp;#180;s leading supplier of HVAC drives Tropical Islands Resort, near Berlin, Germany Grand Hyatt, Dubai Shanghai General Motors, China Drives know-how Nobody knows more about HVAC drives than Danfoss. HVAC is the heart of our company, and our global sales organisation is always ready to serve you, backed by 24-hour technical support. HVAC know-how The Danfoss global HVAC team also commands unsurpassed knowledge of your business. Not only do we supply dedicated products, we also provide advice and assistance in fully integrating these products into your system. Market leading products The Danfoss VLT&amp;#174; HVAC Drive is the ﬂagship product, providing unsurpassed performance, energy savings, dedicated functionality and communication protocols for interfacing with building management systems. Local service – worldwide The high reliability of Danfoss drives means minimal downtime. However, knowing the importance of continuous operation, Danfoss has established a worldwide service organisation to meet your needs at only a moment’s notice. All over the world Danfoss’ knowledge of HVAC applications and expertise in drives are available throughout the world from experienced staﬀ stationed in branch oﬃces and authorised service companies. Local contact – worldwide All customers receive ﬁrst-rate service directly from a local Danfoss representative. This eﬃcient service and communication is provided by people who understand the drives, applications and equipment, as well as the local language, culture and business. 2</description><a10:updated>2009-10-25T11:50:02+01:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=3</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=3</link><title>Danfoss Drives Page 3</title><description>The true potential lies beneath the surface On the surface, a drive is often viewed as a capital expenditure item. However, optimum cost eﬃciency is realised when the drive has been fully integrated into the system. Danfoss’ HVAC expertise can help you conﬁgure and install the drive as a fully integrated system component, identifying real-time installation savings in the system that can virtually oﬀset the initial capital cost of the drive. Below the surface, we are able to maximise the “real” savings, delivering the best return on investment, providing optimum performance and environmental conditions through our extensive experience in integrating Danfoss technology into your new or existing applications. How do we do this? We combine HVAC-designed product functionality, application knowledge and integration expertise, thus delivering lower system costs and optimum energy savings. 3</description><a10:updated>2009-10-25T11:50:02+01:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=4</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=4</link><title>Danfoss Drives Page 4</title><description>How we have dedicated our drives to HVAC Automatic Energy Optimisation (AEO) The drive continuously monitors the relationship between voltage and current in the motor and adjusts the output voltage to minimise current and maximise motor and drive eﬃciency. Four input PID controller The extended PID controllers oﬀer unequaled ﬂexibility. One integral PID controller controls the drive’s speed. Three extended PID controllers provide an output that can be used for additional HVAC control. For retroﬁtting, the integral PID controller and two static pressure transmitters can be used to control supply fan capacity. One transmitter controls the fan motor speed based on system static pressure. The second functions a discharge operating high limit to prevent damage to the duct work. Manual resetting of the duct sensor is eliminated. The additional extended PID controllers can be used for additional HVAC processes – heating or cooling valve control, damper control, etc. Single input PID controller A built-in controller operates independently and eliminates the need for a building automation system to maintain constant ﬂow in systems. A signal from a temperature, pressure, or ﬂow transmitter connected to the drive is all that is required. Multi-zone feedback The drive PID controller oﬀers unequaled ﬂexibility by accepting up to three feedback signals with individual set-points. Multi-zone control provides improved system performance and optimisation. Stand-alone operation The PID controller provides variable air volume features without dependence on a building automation system. This eliminates the need for additional direct digital control and I/O modules. Automatic Switching Frequency Modulation (ASFM) There is no need to derate the drive output at high load. ASFM adjusts the switching frequency based on motor current demand, rather than motor speed. This ensures that the best possible switching frequency is provided, matching both performance and noise control. De-icing Under severe winter weather conditions, it may be necessary to reverse the cooling tower fan to remove accumulated ice from the intake louvers. The VLT&amp;#174; drive can reverse airﬂow direction for timed durations to prevent ice accumulation on both the intake louvers and the exhaust fan blades. Minimum frequency A minimum output frequency ensures suﬃcient fan speed operation for the adequate lubrication of the tower fan gearbox. Frequency bypass The fan motor in the cooling tower steps over speeds that cause mechanical vibration in the tower, preventing potential damage to mechanical components in the system. 4</description><a10:updated>2009-10-25T11:50:02+01:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=5</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=5</link><title>Danfoss Drives Page 5</title><description>Fire Override Mode Primarily used for ﬁre safety applications, the drive can override fan operation to provide a life-safety application, such as building pressurisation or a smoke-purge operation. Broken belt detection The drive monitors the V-belt on a fan, pump or compressor and gives a warning when a malfunction such as a broken belt occurs. Motor soft start Smooth acceleration of the pump reduces noise, peak current, thermal motor load, and mechanical stress to the hot water pump system caused by water hammer. In addition, smooth acceleration extends motor life. High and low feedback warning A selected high and low hot water diﬀerential pressure feedback signal monitored by the VLT&amp;#174; drive can indicate system problems prior to the boiler tripping oﬀ. Metering The local control panel of the drive can be used to display many drive or system operating variables including kWh, hours run, static duct pressure, condenser water return temperature etc. Sleep mode The VLT&amp;#174; drive automatically stops the cooling tower fan when the basin water temperature remains at a low level for a pre-determined amount of time. Minimum speed control Under minimal loads, this feature provides the required minimum air changes in a zone to ensure adequate air quality. Under increased zone loads, such as with occupancy, the fan speed increases to maintain the desired environmental conditions. Automatic restart Automatic power-up after a trip-out enhances automated operation for remotely controlled systems. Run permissive A “system ready” signal prior to operation prevents the drive from starting and ensures that dampers or other system equipment are in the proper state before starting the motor. This feature reduces the number of I/O points and installation costs. High and low frequency warning Useful in staging on or oﬀ additional equipment, such as pumps or fans when the motor speed is either too high or too low. A speciﬁc frequency can be set for warning and to stage external devices on or oﬀ. Motor preheat To extend the life of a motor in a damp environment, a small amount of current can be trickled into the motor to protect it from condensation and the eﬀects of a cold start. 5</description><a10:updated>2009-10-25T11:50:02+01:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=6</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=6</link><title>Danfoss Drives Page 6</title><description>Dedicated drives – all you need is built right in VLT&amp;#174; HVAC Drive IP 20 Panel mount VLT&amp;#174; HVAC Drive VLT&amp;#174; Micro Drive FC51 VLT&amp;#174; 2800 VLT&amp;#174; Drive Motor FCM 300 Features for providing precise and accurate control are standard in the VLT&amp;#174; HVAC Drive FC 100. Integration • Built in RFI ﬁlters protected to 1st environment and EN 61800-3:2004 to Category C2 with 150m of motor cable and Category C1 with 50 m of cable • Built-in DC link coils – reduced harmonic distortion • IP54/55/66 enclosure – fully protected ﬁeld mounting unit • Four input PID controls – two or three feedback lines for multi-zone control • Serial communication – Metasyst&amp;#174; N2, Apogee&amp;#174; FLN, BACnet™, LonWorks&amp;#174;, Modbus RTU, Proﬁbus and DeviceNet Energy saving • Automatic Energy Optimisation (AEO) – reduces energy consumption for lightly loaded motors • Automatic Motor Adaptation (AMA) – optimises motor performance • Sleep mode – the motor is stopped and restarted by system requirements • Temperature-dependent fan – fan operates when required, extending the life of the fan and drive Protection • Unlimited switching on the output of the drive – allows isolation of motor from drive • Earth and short circuit – full fault protection • Skip frequencies – avoids resonance in the system • Automatic derating function – avoids trip of the drive Reliable • High-ambient operation – can tolerate warm environments up to 50&amp;#176; C • Auto-derating – protects the drive from overheating and tripping at extreme operating temperatures above 50&amp;#176; C • Auto-ramping – prevents the drive from tripping when decelerating • Automatic restart – User friendly auto-reset after trip • Local control panel – clear text display readout • Quick Menu set-up – accesses most common settings • Hand-Oﬀ-Auto function – fast and easy commissioning Harmonic ﬁlters VLT&amp;#174; drives have built-in DC link chokes to minimise harmonic distortion of the mains supply. Further harmonic reduction is possible using Danfoss advanced harmonic ﬁlters as stand-alone options. These oﬀer a total harmonic distortion of either 10% or 5%. Real Time Clock The Real Time Clock performs predeﬁned actions. This is a strong tool for controlling HVAC systems where the drives are not connected to a Building Management System (BMS), or if the drive is used as an intelligent component. Preventive Maintenance 20 actions items can be scheduled within the VLT&amp;#174; HVAC Drive to secure planned maintenance and a more reliable HVAC system. Full power range 1.1 kW – 1.2 MW VLT&amp;#174; HVAC Drives are available. Set-up software HVAC installations are easily set up and documented using VLT&amp;#174; Motion Control Tool software (MCT 10). Danfoss Drives provides a range of PC programs for facilitating set-up, commissioning and monitoring drives. The MCT 10 software is used to copy and manage documents, compare previous and present drive settings, print and display data. 6</description><a10:updated>2009-10-25T11:50:02+01:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=7</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=7</link><title>Danfoss Drives Page 7</title><description>Type Power range/ Voltage range VLT&amp;#174; HVAC Drive FC100 1.1 – 45 kW/3 x 200-240 V 1.1 kW – 1.2 MW/ 3 x 380 – 480 V 1.1 kW – 1.2 MW/ 3 x 525 – 600 V IP 00 IP 20 / Chassis IP 21 / NEMA 1 IP 54 IP 55/ NEMA 12 IP 66 Built-in Select from Category: C1 50 m/ C2 150 m C1 10 m/C2 50 m C3 25 m Built-in DC coils Advanced harmonic ﬁlters 10 or 5% THID Choose between numeric, graphical or no control panel VLT&amp;#174; Micro Drive FC51 1 phase 200–240 V AC/ 0.18–2.2 kW 3 phase 200–240 V AC/ 0.25–3.7 kW 3 phase 380–480 V AC/ 0.37–7.5 kW IP 20 Optional: IP 21/NEMA 1 VLT&amp;#174; 2800 0.37 – 1.5 kW/ 1 x 200 – 240 V 0.37 – 4 kW/ 3 x 200 – 240 V 0.75 – 18.5 kW/ 3 x 380 – 480 V IP 20 Optional: IP 21/NEMA 1 FCM 300 0.55 – 7.5 kW/ 3 x 380 – 480 V Enclosure IP 55 Optional: IP 56, IP 66 RFI ﬁlter Built-in Category C1 5 m/C2 15 m Optional: Category C2 (integrated) Category C1 (with external module); integrated in 11 – 18.5 kW) Built-in DC coils Optional: Advanced harmonic ﬁlters 10 or 5% THID Numeric LED/local control (integrated) Optional: Alphanumeric LCD/local control (connectable) Analogue inputs: 2 Digital inputs: 5 Analogue outputs: 1 Digital outputs: 1 Relay outputs: 1 Standard built in: – FC protocol – Metasys N2 – Modbus RTU Optional: – Proﬁbus – DeviceNet Category C2 (integrated) Optional: Category C2 (integrated) Filter for harmonic distortion Optional: Line ﬁlter Built-in DC coils Optional: Advanced harmonic ﬁlters 10 or 5% THID Optional: Alphanumeric LCD/ local control (connectable) and local operation pad (connectable) Analogue inputs: 2 (1) Digital inputs: 3 (4) Digital outputs: 1 or (Analogue outputs: 1) Display/local control Choose between numeric with or without potentiometer and no control panel Analogue inputs: 2 Digital inputs: 5 Pulse inputs: 1 Programmable analogue outputs: 1 Programmable relay outputs: 1 Standard built in: – FC Protocol – Modbus RTU Control inputs Analogue inputs: 2 Digital inputs: 6 (2 can be used as digital ouputs) Programmable analogue outputs: 1 Programmable relay outputs: 2 Standard built in: • FC Protocol • N2 Metasys • FLN Apogee • Modbus RTU Optional: • LonWorks • BACnet • DeviceNet • Proﬁbus Signal outputs Serial communication RS485 Port as standard Optional: Proﬁbus (integrated) Application adaptation I/O Options providing ﬂexibility including Pt1000/Ni1000 inputs, additional analogue outputs, additional relay outputs and Real Time Clock back-up power supply Built-in brake functions Built-in Smart Logic Controller 7</description><a10:updated>2009-10-25T11:50:02+01:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=8</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/SBABrochures/VLTHVAC/?Page=8</link><title>Danfoss Drives Page 8</title><description>What VLT&amp;#174; is all about Danfoss Drives is the world leader among dedicated drives providers – and still gaining market share. Dedicated to drives Dedication has been a key word since 1968, when Danfoss introduced the world’s ﬁrst mass produced variable speed drive for AC motors – and named it VLT&amp;#174;. Two thousand employees develop, manufacture, sell and service drives and soft starters in more than one hundred countries, focused only on drives and soft starters. Intelligent and innovative Developers at Danfoss Drives have fully adopted modular principles in development as well as design, production and conﬁguration. Tomorrow’s features are developed in parallel using dedicated technology platforms. This allows the development of all elements to take place in parallel, at the same time reducing time to market and ensuring that customers always enjoy the beneﬁts of the latest features. Rely on the experts We take responsibility for every element in our products. The fact that we develop and produce our own features, hardware, software, power modules, printed circuit boards, and accessories is your guarantee for reliable products. Local backup – globally VLT&amp;#174; motor controllers are operating in applications all over the world and Danfoss Drives’ experts located in more than 100 countries are ready to support our customers with application advice and service wherever they may be. Danfoss Drives experts don’t stop until the customer’s drive challenges are solved. Protects environment VLT&amp;#174; products are manufactured with respect for environment, safety and well-being. All activities are planned and performed taking into account the individual employee, the work environment and the external environment. Production takes place with a minimum of noise, smoke or other pollution and environmentally safe disposal of the products is assured. UN Global Compact Danfoss has signed the UN Global Compact on social and environmental responsibility and our companies act responsibly towards local societies. EU Directives All factories are certiﬁed according to ISO 14001 standard. All products fulﬁl the EU Directives for General Product Safety and the Machinery directive. Danfoss Drives is, in all product series, implementing the EU Directive concerning Hazardous Substances in Electrical and Electrical Equipment (RoHS) and is designing all new product series according to the EU Directive on Waste Electrical and Electronic Equipment (WEEE). Products’ impact One year’s energy savings from VLT&amp;#174; drives will save the energy equivalent to the energy production from a nuclear power plant. Better process control at the same time improves product quality and reduces waste and wear on equipment. Danfoss Drives, Ulsnaes 1, DK-6300 Graasten, Denmark, Tel. +45 74 88 22 22, Fax +45 74 65 25 80, www.danfoss.com/drives • E-mail: info@danfoss.com DKDD.PB.60.C1.02 VLT&amp;#174; is a trademark of Danfoss A/S Produced by KKM 2007.11</description><a10:updated>2009-10-25T11:50:02+01:00</a10:updated></item></channel></rss>