The VLT® AQUA Drive is innovative – Reduces system, installation and operating costs Danfoss VLT® AQUA Drive is dedicated to wat
• 2-step ramps (initial and final ramp) • Check valve protection • Safe stop • Low flow detection • Pipe fill mode • Sleep mode
Water and Wastewater processes – Improved control using less energy 5 2 1 6 3 4 1 Water treatment plants Meeting the varying flo
7 tighter control of chemical feed pumps, mixers and other equipment. 6 5 hammering and reduces leakage when empty pipes are fil
The modular VLT® AQUA Drive Extremely compact panel mount cabinets 1 – – – – – – 2 Fieldbus option Modbus RTU (std.) Modbus TCP
9 The option protects significantly better against chlorine, hydrogen sulphide, ammonia and other gasses. Unique cooling concept
Dedicated water features Auto tuning of the PI controllers With auto tuning of the PI controllers, the drive monitors how the sy
Dry Run Detection lowers maintenance costs The VLT® AQUA Drive constantly evaluates the condition of the pump, based on internal
AQUA users participated in developing the user interface 1 – – – – – 2 Graphical display International letters and signs Graphic
Specifications Mains supply (L1, L2, L3) Supply voltage 1 or 3 x 200 – 240 V ±10% 1 or 3 x 380 – 480 V ±10% 3 x 525 – 600 V ±10%
Power, currents and enclosures ratings T2 200 – 240 V 1 ph 3 ph ≤440 V T4 380 – 480 V 1 ph Amp. All IP cl.* >440 V Amp. ≤440 V >
Choose configurations freely [1] FC-202 – [2] – [3] – [4] – [5] – [6] – [7] – [8] – [9] – [10] [11] [12] [13] – [14] [15] [16] [
Connection examples The numbers represent the terminals on the drive 3 Phase power input 91 (L1) 92 (L2) 93 (L3) 95 PE 88 (-) 89
Proven AQUA Experience – world wide Freshwater supply for the city Novi Sad, Serbia In the city of Novi Sad in Serbia, Danfoss D
1 x 200 – 240 VAC and 1 x 380 – 480 VAC 1 x 200 – 240 VAC Enclosure IP 20 /Chassis IP 55 + IP 66 /NEMA 12 [kW] [HP] [A] [A] [kVA
3 x 200 – 240 VAC Enclosure IP 20 (IP 21*)/Chassis IP 55 + IP 66 /NEMA 12 [kW] [HP] [A] [A] [kVA] [mm ] ([AWG]) Continuous Inter
380 – 480 VAC Enclosure Typical Shaft Output Typical Shaft Output at 460 V Output Current (3 x 380 – 440 V) Output Current (3 x
380 – 480 VAC Enclosure Typical Shaft Output at 400 V Typical Shaft Output at 460 V Output Current Continuous (3 x 380 – 400 V)
525 – 690 VAC Enclosure IP 20 Chassis IP 21/NEMA 1 IP 55, IP 66/NEMA 12 Typical Shaft Output Output Current Continuous (3 x 525
525 – 690 VAC Enclosure Typical Shaft Output at 550 V Typical Shaft Output at 575 V Typical Shaft Output at 690 V Output Current
Dimensions VLT® AQUA Drive In mm Min. 100 Exhaust 205 (220) Exhaust ∅ 5,5 90 70 A2 Enclosures Min. 100 Inlet 341 Inlet ∅ 5,5 Rea
650 480 420 In mm Min. 200 Inlet Min. 200 Exhaust 242 242 242 Min. 100 Inlet Min. 100 Exhaust Min. 100 Inlet Min. 100 Exhaust Di
Dimensions VLT® AQUA Drive In mm Min. 200 Exhaust 249 (262) ∅ 6,8 Exhaust 165 140 B3 Enclosures Min. 200 Inlet 419 ∅ 6,8 Inlet R
In mm 770 370 Min. 225 Inlet Min. 225 Exhaust Min. 225 Exhaust Min. 200 Inlet Min. 200 Exhaust Min. 225 Inlet 800 36 Inlet Inlet
Dimensions VLT® AQUA Drive In mm D1 Enclosures (Floor- or cabinet Mount) 74 765 m3/hr Min. 22 Exhaust 170 m3/hr 420 1166 1209 98
Dimensions VLT® AQUA Drive In mm 66 408 765 m3/hr Min. 225 Exhaust 255 m3/hr 1046 818 997 147 157 Min. 225 Inlet 375 417 66 765
Dimensions VLT® AQUA Drive In mm 1444 m3/hr 72 Min. 225 Air Space Outlet 340 m3/hr 600 E1 Enclosures (Floor Mount) 2000 1551 164
Dimensions VLT® AQUA Drive In mm 607 1400 Min. 200 Air Space Outlet IP 21/NEMA 1 2100 m3/hr IP 54/NEMA 12 1575 m3/hr 2280 2205 1
Dimensions VLT® AQUA Drive In mm 607 1997 Min. 200 Air Space Outlet IP 21/NEMA 1 1444 m3/hr F3 Enclosures (Floor Mount) IP 54/NE
VLT® AQUA Drive Options A VLT® PROFIBUS DP V1 MCA 101 • PROFIBUS DP V1 gives you wide compatibility, a high level of availabilit
VLT® AQUA Drive Options Typecode Position B C VLT® General Purpose I/O MCB 101 The I/O option offers an extended number of contr
VLT® AQUA Drive Options D VLT® 24 V DC Supply Option MCB 107 The option is used to connect an external DC supply to keep the con
VLT® AQUA Drive Accessories Profibus Adapter Sub-D9 Connector The adapter makes linking of fieldbus connections pluggable. For u
VLT® AQUA Drive Accessories VLT® Harmonic Filter AHF 005/010 MCE Easy, effective harmonic distortion reduction by connecting the
What VLT® is all about Danfoss Drives is the world leader among dedicated drives providers – and still gaining market share. Ded
Page 1:
MAKING MODERN LIVING POSSIBLE New photo VLT® AQUA Drive
Page 2:
The VLT® AQUA Drive is innovative – Reduces system, installation
Page 3:
• 2-step ramps (initial and final ramp) • Check valve protection
Page 4:
Water and Wastewater processes – Improved control using less ene
Page 5:
7 tighter control of chemical feed pumps, mixers and other equip
Page 6:
The modular VLT® AQUA Drive Extremely compact panel mount cabine
Page 7:
9 The option protects significantly better against chlorine, hyd
Page 8:
Dedicated water features Auto tuning of the PI controllers With
Page 9:
Dry Run Detection lowers maintenance costs The VLT® AQUA Drive c
Page 10:
AQUA users participated in developing the user interface 1 – – –
Page 11:
Specifications Mains supply (L1, L2, L3) Supply voltage 1 or 3 x
Page 12:
Power, currents and enclosures ratings T2 200 – 240 V 1 ph 3 ph
Page 13:
Choose configurations freely [1] FC-202 – [2] – [3] – [4] – [5]
Page 14:
Connection examples The numbers represent the terminals on the d
Page 15:
Proven AQUA Experience – world wide Freshwater supply for the ci
Page 16:
1 x 200 – 240 VAC and 1 x 380 – 480 VAC 1 x 200 – 240 VAC Enclos
Page 17:
3 x 200 – 240 VAC Enclosure IP 20 (IP 21*)/Chassis IP 55 + IP 66
Page 18:
380 – 480 VAC Enclosure Typical Shaft Output Typical Shaft Outpu
Page 19:
380 – 480 VAC Enclosure Typical Shaft Output at 400 V Typical Sh
Page 20:
525 – 690 VAC Enclosure IP 20 Chassis IP 21/NEMA 1 IP 55, IP 66/
Page 21:
525 – 690 VAC Enclosure Typical Shaft Output at 550 V Typical Sh
Page 22:
Dimensions VLT® AQUA Drive In mm Min. 100 Exhaust 205 (220) Exha
Page 23:
650 480 420 In mm Min. 200 Inlet Min. 200 Exhaust 242 242 242 Mi
Page 24:
Dimensions VLT® AQUA Drive In mm Min. 200 Exhaust 249 (262) ∅ 6,
Page 25:
In mm 770 370 Min. 225 Inlet Min. 225 Exhaust Min. 225 Exhaust M
Page 26:
Dimensions VLT® AQUA Drive In mm D1 Enclosures (Floor- or cabine
Page 27:
Dimensions VLT® AQUA Drive In mm 66 408 765 m3/hr Min. 225 Exhau
Page 28:
Dimensions VLT® AQUA Drive In mm 1444 m3/hr 72 Min. 225 Air Spac
Page 29:
Dimensions VLT® AQUA Drive In mm 607 1400 Min. 200 Air Space Out
Page 30:
Dimensions VLT® AQUA Drive In mm 607 1997 Min. 200 Air Space Out
Page 31:
VLT® AQUA Drive Options A VLT® PROFIBUS DP V1 MCA 101 • PROFIBUS
Page 32:
VLT® AQUA Drive Options Typecode Position B C VLT® General Purpo
Page 33:
VLT® AQUA Drive Options D VLT® 24 V DC Supply Option MCB 107 The
Page 34:
VLT® AQUA Drive Accessories Profibus Adapter Sub-D9 Connector Th
Page 35:
VLT® AQUA Drive Accessories VLT® Harmonic Filter AHF 005/010 MCE
Page 36:
What VLT® is all about Danfoss Drives is the world leader among
Danfoss Drives
Click here to download the catalog as a PDF file.