<?xml version="1.0" encoding="utf-16"?><rss xmlns:a10="http://www.w3.org/2005/Atom" version="2.0"><channel><title>Danfoss Drives</title><link>http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/RSS.ashx</link><description>Danfoss Drives Pages</description><lastBuildDate>Sat, 15 Aug 2009 23:38:20 +0200</lastBuildDate><a10:id>http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/</a10:id><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=1</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=1</link><title>Danfoss Drives Page 1</title><description>MAKING MODERN LIVING POSSIBLE Option Overview VLT&amp;#174; HVAC Drive, VLT&amp;#174; AQUA Drive and VLT&amp;#174; AutomationDrive</description><a10:updated>2009-08-15T23:38:20+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=2</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=2</link><title>Danfoss Drives Page 2</title><description>Slot A All options are built in and tested at the factory VLT&amp;#174; PROFIBUS DP V1 MCA 101 Operating the frequency converter via a ﬁeld bus lets you reduce the cost of your system, communicate faster and more eﬃciently, and beneﬁt from an easier user interface. • PROFIBUS DP V1 gives you wide compatibility, a high level of availability, support for all major PLC vendors, and compatibility with future versions Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1100 uncoated 130B1200 coated ● • Fast, eﬃcient communication, transparent installation, advanced diagnosis and parameterisation and auto-conﬁguration of process data via GSD-ﬁle • A-cyclic parameterisation using PROFIBUS DP V1, PROFIdrive or Danfoss FC proﬁle state machines, PROFIBUS DP V1, Master Class 1 and 2 VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● VLT&amp;#174; DeviceNet MCA 104 DeviceNet oﬀers robust, eﬃcient data handling thanks to advanced Producer/Consumer technology. • This modern communications model oﬀers key capabilities that let you eﬀectively determine what information is needed and when Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1102 uncoated 130B1202 coated ● VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● • You will also beneﬁt from ODVA’s strong conformance testing policies, which ensure that products are interoperable VLT&amp;#174; CAN Open MCA 105 High ﬂexibility and low cost are two of the “cornerstones” for CAN Open. The CAN Open option for the AutomationDrive is fully equipped with both high priority access to control and status of the Drive (PDO Communication) and access to all Parameters through acyclic data (SDO Communication). Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1103 uncoated 130B1205 coated For interoperability the option has implemented the DSP402 AC drive Proﬁle. This all guarantees standardised handling, interoperability and low cost. VLT&amp;#174; AQUA Drive FC 202 VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● VLT&amp;#174; LonWorks MCA 108 LonWorks is a ﬁeldbus system developed for building automation. It enables communication between individual units in the same system (peer-to-peer) and thus supports decentralising of control. • No need for big main station (master-follower) • Units receive signals directly • Supports Echelon free-topology interface (ﬂexible cabling and installation) • Supports embedded I/Os and I/O options (easy implementation of de-central I/Os) • Sensor signals can quickly be moved to another controller via bus cables • Certiﬁed as compliant with LonMark ver. 3.4 speciﬁcations VLT&amp;#174; AutomationDrive FC 301 FC 302 Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 130B1106 uncoated 130B1206 coated ● 2</description><a10:updated>2009-08-15T23:38:20+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=3</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=3</link><title>Danfoss Drives Page 3</title><description>Slot A VLT&amp;#174; BACnet MCA 109 The open communications protocol for worldwide building automation use. The BACnet protocol is an international protocol that eﬃciently integrates all parts of building automation equipment from the actuator level to the building management system. • BACnet is the world standard for building automation • International standard ISO 16484-5 Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1144 uncoated 130B1244 coated ● • With no license fees, the protocol can be used in building automation systems of all sizes • The BACnet option lets the drive communicate with building management systems running the BACnet protocol • Typical areas where BACnet is used include heating, ventilation, cooling and climate equipment control • The BACnet protocol is easily integrated into existing control equipment networks VLT&amp;#174; AutomationDrive FC 301 FC 302 VLT&amp;#174; AQUA Drive FC 202 VLT&amp;#174; EtherNet IP MCA 121 EtherNet will become the future standard for communication at the factory ﬂoor. The EtherNet Option is based on the newest technology available for the Industrial use and handles even the most demanding requirements. EtherNet/IP extends commercial oﬀthe-shelf EtherNet to the Common Industrial Protocol (CIP™) – the same upper-layer protocol and object model found in DeviceNet. Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1119 uncoated 130B1219 coated The VLT&amp;#174; MCA 121 oﬀers advanced features as: • Built-in high performance switch enabling line-topology, and eliminating the need for external switches • Advanced switch and diagnoses functions • Built-in web server • E-mail client for service notiﬁcation VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● VLT&amp;#174; 3000 Converter MCA 113 The conversion kit is a special version of the ﬁeldbus options that emulates the VLT&amp;#174; 3000 commands in the VLT&amp;#174; AutomationDrive. This is useful for users who want to keep the PLC program. The VLT&amp;#174; 3000 can then be replaced by the VLT&amp;#174; AutomationDrive, or the system can be expanded without costly change of the PLC program. For upgrade to a diﬀerent ﬁeldbus, the installed converter is easily removed and replaced with a new option. This secures the investment without losing ﬂexibility. Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 VLT&amp;#174; AutomationDrive FC 301 FC 302 ● NA uncoated 130B1245 coated VLT&amp;#174; 5000 Converter MCA 114 The conversion kit is a special version of the ﬁeldbus options that emulates the VLT&amp;#174; 5000 commands in the VLT&amp;#174; AutomationDrive. This is useful for users who want to keep the PLC program. The VLT&amp;#174; 5000 can then be replaced by the VLT&amp;#174; AutomationDrive, or the system can be expanded without costly change of the PLC program. For upgrade to a diﬀerent ﬁeldbus, the installed converter is easily removed and replaced with a new option. This secures the investment without losing ﬂexibility. The option supports DPV1. Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 VLT&amp;#174; AutomationDrive FC 301 FC 302 ● NA uncoated 130B1246 coated 3</description><a10:updated>2009-08-15T23:38:20+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=4</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=4</link><title>Danfoss Drives Page 4</title><description>Slot B All options are built in and tested at the factory VLT&amp;#174; General Purpose I/O MCB 101 I/O option oﬀers an extended number of control inputs and outputs. • 3 digital inputs 0-24 V: Logic ‘0’ &amp;lt; 5 V; Logic ‘1’ &amp;gt; 10V • 2 analogue inputs 0-10 V: Resolution 10 bit plus sign Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1125 uncoated 130B1212 coated ● • • • • 2 digital outputs NPN/PNP push pull 1 analogue output 0/4-20 mA Spring loaded connection Separate parameter settings VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● VLT&amp;#174; Encoder Input MCB 102 A universal option for connection of encoder feedback from either a motor or a process. Feedback for asynchronous or brushless servo (Permanent Magnet) motors. • Encoder module supports: – Incremental encoders – SinCos encoders as Hyperface&amp;#174; Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1115 uncoated 130B1203 coated Power supply for encoders RS422 interface Plug-and-Play principle Fit to all FC 300 AutomationDrives Connection to all standard 5 V incremental encoders • Spring-loaded connection • • • • • VLT&amp;#174; AQUA Drive FC 202 VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● VLT&amp;#174; Resolver Input MCB 103 Supports resolver feedback from brushless servo motors, and feedback for ﬂux vector controlled asynchronous motors in rough environment. • • • • • • Primary Voltage .2 -8 Vrms Primary Frequency .2.0 kHz – 15 kHz Primary current max .50 mA rms Secondary input voltage .4 Vrms Spring loaded connection Separate parameter settings VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 130B1127 uncoated 130B1227 coated VLT&amp;#174; Relay Option MCB 105 Lets you extend relay functions with 3 additional relay outputs. Max. terminal load: • AC-1 Resistive load . 240 V AC 2 A • AC-15 Inductive load @cos ﬁ 0.4 .240 V AC 0.2 A • DC-1 Resistive load . 24 V DC 1 A • DC-13 Inductive load @cos ﬁ 0.4 .24 V DC 0.1 A Min. terminal load: • DC 5 V . 10 mA • Max switch rate at rated load/min. load . 6 min-1/20 sec-1 • Plug-and-play principle, ﬁts into slot B • Protects control cable connection • Spring-loaded control wire connection • Selection of relay functions in normal parameter settings Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● 130B1110 uncoated 130B1210 coated ● 4</description><a10:updated>2009-08-15T23:38:20+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=5</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=5</link><title>Danfoss Drives Page 5</title><description>Slot B VLT&amp;#174; Safe PLC I/O MCB 108 The FC 302 provides a safety input based on a single pole 24 V DC input. • For the majority of applications this input enables the user to implement safety in a cost-eﬀective way. For application that works with more advanced products like Safety PLC, Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1120 uncoated 130B1220 coated Lightcurtains etc. the new Safe PLC interface enables the connection of a two wire safety link • The Safe PLC Interface allows the Safe PLC to interrupt on the plus or the minus link without interfering the sense signal of the Safe PLC VLT&amp;#174; AutomationDrive FC 301 FC 302 ● VLT&amp;#174; AQUA Drive FC 202 VLT&amp;#174; Analog I/O Option MCB 109 This Analog input/output option is easily ﬁtted in the frequency converter for upgrading to advanced performance and control using the additional in/outputs.This option also upgrades the frequency converter with a battery back-up supply for the clock built into the frequency converter. This provides stable use of all frequency converter clock functions as timed actions etc. • 3 analogue inputs, each conﬁgurable as both voltage and temperature input • Connection of 0-10 V analogue signals as well as PT1000 and NI1000 temperature inputs • 3 analogue outputs each conﬁgurable as 0-10 V outputs • Incl. Back-up supply for the standard clock function in the frequency converter The back-up battery typically lasts for 10 years, depending on environment. Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1143 uncoated 130B1243 coated ● VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 FC 302 VLT&amp;#174; PTC Thermistor Card MCB 112 With the MCB 112 PTC Thermistor Card, the Danfoss VLT&amp;#174; AutomationDrive FC 302 now oﬀers improved surveillance of the motor condition compared to the built-in ETR function and thermistor terminal. Ordering number VLT&amp;#174; HVAC Drive FC 102 NA uncoated 130B1137 coated • Protects the motor from overheating • ATEX approved for use in potentially explosive atmospheres • Uses Safe Stop function, which is approved in accordance with Cat. 3 EN954-1 VLT&amp;#174; AQUA Drive FC 202 VLT&amp;#174; AutomationDrive FC 301 FC 302 ● VLT&amp;#174; Sensor Input Card MCB 114 The option protects the motor from being overheated by monitoring the bearings and windings temperature in the motor. The limits as well as the action are adjustable and the individual sensor temperature is visible as a read out in the display or by ﬁeld bus. Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1172 uncoated 130B1272 coated • Protects the motor from overheating • Three self-detecting sensor inputs for 2 or 3 wire PT100/PT1000 sensors • One additional analogue input 4-20mA VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 FC 302 5</description><a10:updated>2009-08-15T23:38:20+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=6</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=6</link><title>Danfoss Drives Page 6</title><description>Slot B All options are built in and tested at the factory VLT&amp;#174; Extended Cascade Controller MCO 101 Easily ﬁtted and upgrades the built-in cascade controller to operate more pumps and more advanced pump control in master/follower mode. • Up to 6 pumps in standard cascade setup • Up to 5 pumps in master/follower setup • Technical speciﬁcation: See MCB 105 Relay Option Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 FC 302 130B1118 uncoated 130B1218 coated USB extension USB extension for IP 55 and IP 66 enclosures. Makes the USB connector available outside the drive. The USB extension is designed for mounting in a cable gland in the bottom of the drive, which makes PC communication very easy even in drives with high IP rating. USB extension for A5-B1 enclosures, 350 mm cable . 130B1155 USB extension for B2-C enclosures, 650 mm cable . 130B1156 Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 ● ● VLT&amp;#174; AutomationDrive FC 301 ● ● FC 302 ● ● 130B1155 350 mm cable 130B1156 650 mm cable ● ● Slot C All options are built in and tested at the factory VLT&amp;#174; Advanced Cascade Controller MCO 102 Easily ﬁtted and upgrades the built-in cascade controller to operate up to 8 pumps and more advanced pump control in master/follower mode. The same cascade controller hardware goes for for the entire power range up to 1.2 MW. Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1154 uncoated 130B1254 coated • Up to 8 pumps in standard cascade setup • Up to 8 pumps in master/follower setup VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 FC 302 VLT&amp;#174; Extended Relay Card MCB 113 The Extended Relay Card MCB 113 adds inputs/ outputs to VLT&amp;#174; AutomationDrive for increased ﬂexibility. • • • • • 7 digital inputs 2 analogue outputs 4 SPDT relays Meets NAMUR recommendations Galvanic isolation capability VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 130B1164 uncoated 130B1264 coated 6</description><a10:updated>2009-08-15T23:38:20+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=7</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=7</link><title>Danfoss Drives Page 7</title><description>Slot C VLT&amp;#174; Motion Control MCO 305 An integrated programmable Motion Controller for VLT&amp;#174; AutomationDrive FC 301 and FC 302; it adds fuctionality and ﬂexibility to the already very comprehensive standard functionality of these drives. MCO 305 is optimised for all types of positioning and synchronising applications. • Basic features: Synchronisation (electronic shaft), Positioning and electronic Cam control • 2 inputs supporting both incremental and absolute encoders • 1 encoder output (virtual master function) • 10 digital inputs • 8 digital outputs • Sending and receiving data via ﬁeldbus interface (requires ﬁeldbus option) • PC software tools for programming and commissioning VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 130B1134 uncoated 130B1234 coated VLT&amp;#174; Synchronizing Control MCO 350 The Synchronizing Controller option for VLT&amp;#174; AutomationDrive expands the functional properties of the converter in synchronising applications. It replaces traditional mechanical solutions. • Display of actual synchronising error on frequency converter control panel • Speed synchronising Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1152 uncoated 130B1252 coated • Position (angle) synchronising with or without marker correction • On-line adjustable gear ratio • On-line adjustable position (angle) oﬀset • Encoder output with virtual master function for synchronization of multiple followers • Homing VLT&amp;#174; AQUA Drive FC 202 VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● VLT&amp;#174; Positioning Control MCO 351 The Positioning Controller option oﬀers a host of user-friendly beneﬁts for positioning applications in many industries. They are based on a range of thought-through and innovative features. • Direct positioning via Fieldbus • Relative positioning • Absolute positioning Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1153 uncoated 130B1253 coated • Touch probe positioning • End limit handling (software and hardware) • Mechanical brake handling (programmable hold delay) • Error handling • Jog speed/manual operation • Marker related positioning • Home function VLT&amp;#174; AQUA Drive FC 202 VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● VLT&amp;#174; Center Winder MCO 352 With the closed loop center winder control material is evenly wound up regardless of the production speed. • Follows line speed • Diameter calculator adjusts winder reference • Tension PID adjusts reference Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● 130B1165 uncoated 130B1266 coated 7</description><a10:updated>2009-08-15T23:38:20+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=8</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=8</link><title>Danfoss Drives Page 8</title><description>Slot D All options are built in and tested at the factory VLT&amp;#174; 24 V DC Supply Option MCB 107 The option is used to connect an external DC supply to keep the control section and any installed option active by mains power down. • Input voltage range .24 V DC +/- 15% (max. 37 V in 10 sec.) • Max. input current . 2.2 A • Max. cable length . 75 m Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1108 uncoated 130B1108 coated ● • • • • Input capitance load .&amp;lt; 10 uF Power-up delay .&amp;lt; 0.6 s Easy to install in drives in existing machines Keep the control board and options active by power cut • Keep ﬁeldbuses active by power cuts VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● LCP All options are built in and tested at the factory LCP 102 Graphical Local Control Panel • • • • Multi-language display Status messages Quick menu for easy commissioning Parameter setting and explanation of parameter function • Adjusting of parameters • Full parameter backup and copy function Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1107 ● • Alarm logging • Info button – explains the function of the selected item on display • Hand-operated start/stop, or Automatic mode selection • Reset function • Trend graph VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● LCP 101 Numerical Local Control Panel The numerical control panel oﬀers an excellent MMI interface to the drive. Status messages Quick menu for easy commissioning Parameter setting and adjusting Hand-operated start/stop function or Automatic mode select • Reset function VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● • • • • Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1124 ● LCP Panel Mounting Kit Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1113 – Incl. graphical LCP, fasteners, 3 m cable and gasket 130B1114 – Incl. numerical LCP, fasteners and gasket 130B1117 – Mounting kit for all LCP’s including fasteners, 3 m cable and gasket 130B1129 LCP front mounting IP55/IP66 130B1170 Panel Mouting Kit for all LCP w.o. cable ● VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 8</description><a10:updated>2009-08-15T23:38:20+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=9</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=9</link><title>Danfoss Drives Page 9</title><description>Accessories For use with option A Profibus Adapter Sub-D9 Connector The adapter makes linking of ﬁeldbus connections pluggable. Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1112 ● VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● For use with option A Decoupling Plate for Fieldbus Cables Strengthens ﬁeldbus mounting. Ordering number VLT&amp;#174; HVAC Drive FC 102 130B0524 To be used only for IP 20/NEMA type 1 units up to 7.5 kW ● VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● VLT&amp;#174; A/B in C Option Adapter MCF 106 The A/B in C Option Adapter can be placed in the Option C slot and allows for up to four Aand B-options in diﬀerent combinations. Limitations are due to the facts – that the drive cannot handle more than one ﬁeldbus at the time, cannot handle several identical options, and that the physical layout of options can cause limitations. Ordering number VLT&amp;#174; HVAC Drive FC 102 130B1130 uncoated 130B1230 coated VLT&amp;#174; Relay Card MCB 105 and VLT&amp;#174; PTC Thermistor Card MCB 112 are not supported by the adapter and must thus only be installed in the standard slot B of the Control Card. VLT&amp;#174; AQUA Drive FC 202 VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● IP 21/Type 12 (NEMA1) Kit The IP 21/Type 12 (NEMA1) kit is used for installation of VLT&amp;#174; drives in dry environments. The enclosure kits are available for frame sizes A1, A2, A3, B3, B4, C3 and C4 • Supports VLT&amp;#174; drives from 1.1 to 90 kW • Used on standard VLT&amp;#174; drive with or without mounted option modules • IP 41 on top side • PG 16 and PG 21 holes for glands VLT&amp;#174; AutomationDrive FC 301 ● ● ● ● ● ● ● FC 302 ● ● ● ● ● ● ● Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 ● ● ● ● ● ● ● 130B1121 For frame size A1 130B1122 For frame size A2 130B1123 For frame size A3 130B1187 For frame size B3 130B1189 For frame size B4 130B1191 For frame size C3 130B1193 For frame size C4 ● ● ● ● ● ● ● 9</description><a10:updated>2009-08-15T23:38:20+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=10</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=10</link><title>Danfoss Drives Page 10</title><description>Power Options VLT&amp;#174; Brake Resistors Energy generated during braking is absorbed by the resistors, protecting electrical components from heating up. Danfoss brake resistors cover the full power range. • Quick braking of heavy load • Braking energy is only absorbed into the brake resistor • External mounting makes it possible to use the generated heat • All necessary approvals are available VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 ● See relevant Design Guide ● VLT&amp;#174; Harmonic Filter AHF 005/010 MCE Easy, eﬀective harmonic distortion reduction by connecting the AHF 005/010 harmonic ﬁlter in front of a Danfoss frequency converter. • AHF 005 reduces total harmonic current distortion to 5% • AHF 010 reduces total harmonic current distortion to 10% • Small compact housing that ﬁts into a panel • Easy to use in retroﬁt applications • User-friendly start-up – no adjustment necessary • No routine maintenance required VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 ● See relevant Design Guide ● VLT&amp;#174; Sine-Wave Filters MCC 101 Sine-wave ﬁlters are placed between the frequency converter and the motor to optimise the motor power current. It provides a sinusoidal phase-to-phase motor voltage. The ﬁlters reduce motor insulation stress, acoustic noise from the motor, and bearing currents (especially in large motors). • Reduce motor insulation stress • Reduce acoustic noise from the motor • Reduce bearing currents (especially in large motors) • Enables use of longer motor cables • Reduce losses in the motor • Prolongs service lifetime Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● See relevant Design Guide ● VLT&amp;#174; dU/dt filter MCC 102 VLT&amp;#174; dU/dt ﬁlters are placed between the frequency converter and the motor to eliminate very fast voltage changes. The motor terminal phase-to-phase voltage is still pulse shaped but its dU/dt values are reduced. • These ﬁlters reduce stress on the motor’s insulation and are recommended in applications with older motors, aggressive environments or frequent braking which cause increased DC link voltage. Ordering number VLT&amp;#174; HVAC Drive FC 102 VLT&amp;#174; AQUA Drive FC 202 ● VLT&amp;#174; AutomationDrive FC 301 ● FC 302 ● See relevant Design Guide ● 10</description><a10:updated>2009-08-15T23:38:20+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=11</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=11</link><title>Danfoss Drives Page 11</title><description>11</description><a10:updated>2009-08-15T23:38:20+02:00</a10:updated></item><item><guid isPermaLink="true">http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=12</guid><link>http://danfoss.ipapercms.dk/Drives/DD/Global/Products/FC/VLTAQUADrive/FCOptionOverview/?Page=12</link><title>Danfoss Drives Page 12</title><description>What VLT&amp;#174; is all about Danfoss Drives is the world leader among dedicated drives providers – and still gaining market share. Dedicated to drives Dedication has been a key word since 1968, when Danfoss introduced the world’s ﬁrst mass produced variable speed drive for AC motors – and named it VLT&amp;#174;. Twentyﬁve hundred employees develop, manufacture, sell and service drives and softstarters in more than one hundred countries, focused only on drives and soft starters. Intelligent and innovative Developers at Danfoss Drives have fully adopted modular principles in development as well as design, production and conﬁguration. Tomorrow’s features are developed in parallel using dedicated technology platforms. This allows the development of all elements to take place in parallel, at the same time reducing time to market and ensuring that customers always enjoy the beneﬁts of the latest features. Rely on the experts We take responsibility for every element of our products. The fact that we develop and produce our own features, hardware, software, power modules, printed circuit boards, and accessories is your guarantee of reliable products. Local backup – globally VLT&amp;#174; motor controllers are operating in applications all over the world and Danfoss Drives’ experts located in more than 100 countries are ready to support our customers with application advice and service wherever they may be. Danfoss Drives experts don’t stop until the customer’s drive challenges are solved. Environmentally responsible VLT&amp;#174; products are manufactured with respect for the safety and well-being of people and the environment. All activities are planned and performed taking into account the individual employee, the work environment and the external environment. Production takes place with a minimum of noise, smoke or other pollution and environmentally safe disposal of the products is prepared. UN Global Compact Danfoss has signed the UN Global Compact on social and environmental responsibility and our companies act responsibly towards local societies. EU Directives All factories are certiﬁed according to ISO 14001 standard. All products fulﬁl the EU Directives for General Product Safety and the Machinery directive. Danfoss Drives is, in all product series, implementing the EU Directive concerning Hazardous Substances in Electrical and Electrical Equipment (RoHS) and is designing all new product series according to the EU Directive on Waste Electrical and Electronic Equipment (WEEE). Impact on energy savings One year’s energy savings from the annual production of VLT&amp;#174; drives will save the energy equivalent to the energy production from a power plant. Better process control at the same time improves product quality and reduces waste and wear on equipment. Danfoss Drives, Ulsnaes 1, DK-6300 Graasten, Denmark, Tel. +45 74 88 22 22, Fax +45 74 65 25 80, www.danfoss.com/drives • E-mail: info@danfoss.com DKDD.PB.39.A1.02 VLT&amp;#174; is a trademark of Danfoss A/S Produced by DD-SMCC 2008.09</description><a10:updated>2009-08-15T23:38:20+02:00</a10:updated></item></channel></rss>